Product Description
PHS-3CA Laboratory PH Meter
PH-3CA is a PH meter with the most powerful functions and the most convenient operation on the market. In the aspects of the intelligence, the measuring property, the usage environment as well as the external structure, great improvement has been made, so the accuracy of the instruments is very high. It can be widely used for continuous monitoring of PH values of the solutions in thermal power plants, chemical fertilizer, alloy, environmental protection, pharmaceutical, biochemical, foodstuff, running water, etc.
Features
Double-row nixie tubes display PH value/mV value and temperature respectively. |
Computer-based: It adopts high-performance CPU chip, high-precision AD conversion technology and SMT |
technology to complete the multi-parameter measurement, automatic temperature compensation and instrument |
self-checking, with high precision and good repeatability. |
Reliability: Single board structure, touch button, no switch knob |
25ºC Conversion: Nernst electrode slope temperature compensation, pure water and ultra-pure water with |
addition of ammonia converted at 25ºC. |
Standard liquid temperature auto-conversion: It pre-stores the temperature curve of the standard liquid; in the |
calibration, it can convert pH value of the standard liquid automatically at the set temperature. |
Auto-determination of error calibration: If the user wrongly uses the standard buffer solution in the calibration, |
the instrument will prompt automatically. |
Technical Indexes
1.Display: The double-row Nixie tube shows PH value/mV value and the temperature respectively. |
2.Measuring range: 0~14.00pH, -l999~ +1999mV, 0~99.9ºC |
3.Resolution: 0.001 PH/0.01PH, 0.1mV, 0.1ºC |
4.Accuracy: ±0 005pH, ±0 2mV, ±0 3ºC |
5.Temperature compensation range: automatic: 0~99.9ºC, manual: 0~99.9ºC |
6.Input impedance: > 1012Ω |
7.Communication interface: RS232 bi-directional communication |
8.Temperature compensation: Nernst electrode slope temperature compensation, |
pure water and ultra-pure water with addition of ammonia converted at 25ºC. |
9.Output: 0~1400mV |
10.Power supply: AC220V ± 22V, 50Hz ± 1Hz |
11.Working conditions: ambient temperature: 0-60ºC; relative humidity: ≤90% |
12.Power-down memory: > 5 years |
13.Calibration mode: One-point calibration, two-point calibration |
Standard configuration
One secondary instrument; one power supply; one 2-in-1 electrode, one temperature electrode; a set of electrode |
support, a set of standard buffer solution |