Power Rate(w) | backup time(H) @1*100Ah | backup time(H) @2*100Ah | backup time(H) @4*100Ah | backup time(H) @4*200Ah | backup time(H) @8*200Ah |
---|---|---|---|---|---|
1000 | 0.4806 | 1.602 | 3.50304 | 7.6896 | |
2000 | 0.2136 | 0.4806 | 1.602 | 3.50304 | 7.6896 |
3000 | 0.1068 | 0.2848 | 0.8544 | 2.136 | 4.8416 |
MODEL | EP30-1KW PRO | EP30-1.5KW PRO | EP30-2KW PRO | EP30-3KW PRO | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Default Battery System Voltage | 12VDC | 24VDC | 12VDC | 24VDC | 12VDC | 24VDC | 12VDC | 24VDC | 48VDC | |
INVERTER OUTPUT | Reted Power | 1.0KW | 1.5KW | 2KW | 3KW | |||||
Surge Rating (20ms) | 3.0KVA | 4.5KVA | 6.0KVA | 9.0KVA | ||||||
Capable Of Starting Electric Motor | 1HP | 1HP | 1HP | 2HP | ||||||
Waveform | Pure sine wave/ same as input (bypass mode) | |||||||||
Nominal Output Voltage RMS | 100V/110V/120VAC 220V/230V/240VAC(±10% RMS) | |||||||||
Output Frequency | 5OHz/60Hz±0.3 Hz | |||||||||
Inverter Efficiency(Peak) | >88% | |||||||||
Line Mode Efficiency | >95% | |||||||||
Power Factor | 1.0 | |||||||||
Typical Transfer Time | 10ms(max) 10ms(max) | |||||||||
AC INPUT | Voltage | 230VAC | ||||||||
Selectable Voltage Range | 96~132VAC 155~280VAC(For Personal Computers) | |||||||||
Frequency Range | 50Hz/60Hz (Auto sensing) 40~80Hz | |||||||||
BATTERY | Minimum Start Voltage | 10.0VDC /10.5VDC for12VDC mode (*2 for 24VDC, ) | ||||||||
Low Battery Alarm | 10.5VDC±0.3V for12VDC mode (*2 for 24VDC, ) | |||||||||
Low Battery Cutoff | 10.0VDC±0.3V for12VDC mode (*2 for 24VDC, ) | |||||||||
High Voltage Alarm | 16.0VDC±0.3V for12VDC mode (*2 for 24VDC, ) | |||||||||
High Battery Voltage Recover | 15.5VDC±0.3V for12VDC mode (*2 for 24VDC, ) | |||||||||
Idle Consumption-Search Mode | <25W when power saver on | |||||||||
CHARGER | Output Voltage | Depends on battery tvpe | ||||||||
Charger AC Input Breaker Rrating | 10A | 30A | 30A | 30A | ||||||
Overcharge Protection S.D. | 15.7VDC for 12VDC mode (*2 for 24VDC mode) | |||||||||
Maximum Charge Current | 35A | 20A | 45A | 25A | 65A | 35A | 75A | 45A | 30A | |
BYPASS & PROTECTION | Input Voltage Waveform | Sine wave (grid or generator) | ||||||||
Nominal Input Frequency | 50Hz or 60Hz | |||||||||
Overload Protection (SMPS Load) | Circuit breaker | |||||||||
Output Short Circuit Protection | Circuit breaker | |||||||||
Bypass Breaker Rating | 10A | 30A | 30A | 30A | ||||||
Max Bypass Current | 30Amp | |||||||||
SOLAR CHARGER | Maximum PV Charge Current | 50A | ||||||||
DC Voltage | 12V/24V/48 | |||||||||
PWM Range @ Operating Voltage | 15~80VDC | |||||||||
Maximum PV Array Open Circuit Voltage | 90VDC | |||||||||
Maximum Efficiency | >97% | |||||||||
Standby Power Consumption | <2W | |||||||||
MECHANICAL SPECIFICATIONS | Mounting | Wall mount | ||||||||
Dimensions (W*H*D) | 426*206*178 mm | |||||||||
Net Weight (Solar CHG) kg | 16.5 | 17 | 21.1 | 20 | 26 | 24.5 | 24.8 | |||
Shipping Dimensions(W*H*D) | 570*335*300mm | |||||||||
Shipping Weight (Solar CHG) kg | 19.3 | 20 | 24.1 | 22.8 | 29.1 | 27.5 | 27.5 | |||
OTHER | Operation Temperature Range | 0°C to 40°C | ||||||||
Storage Temperature | -15°C to 60°C | |||||||||
Audible Noise | 60dB MAX | |||||||||
Display | LED+LCD | |||||||||
Standard Warranty | 1 year |
Company Information
Shenzhen Must Energy Technology Co., Ltd
1.Customer Feedback
Our R&D team have tested your UPS, they are satisfied with the performance of the sample. All the test results are complying with the specification. We are highly appreciated it. --- N. Raja (from Chennai, India)
We are quite impressive with the IGBT function of this UPS. We are now trying to apply this model on our telecommunication systems. --- Robert Alles (from Munich, Germany)
2.Order information
Trade term: FOB Shenzhen / Hongkong
Delivery time: 7-21 days after confirmed the order
Packaging Detail:Standard export carton or OEM package
3.Warranty term
1. Under the terms of this warranty, if failure occurs under normal usage within warranty period, Helior Technology will provide free maintenance based on the proof-documents.
2. If Failure or damage occurs due to incorrect operation, wire connection, or any other mis-opeartions, Helior Technology will provide pay maintenance on charge basis.
1.Package: Carton Box for packaging, or Wooden Box advised for Samples to protect in transportations. Package designed by Clients is welcomed.
2.Shipping: DHL,FEDEX,UPS,EMS,AirWay and By Sea.
3.Payment: T/T( telegraphic transfer (T/T) and Western Union
4.Welcome to your Sample Order to test First.