adapter 100v-240v output 5v 10a power supply 5v 10a adapter
SPECIFICATION |
OUTPUT |
Model | power supply | power supply |
DC Voltage | 5V | 5V |
Rated Current | 10A | 10A |
Current Range | 0-2.5A | 0-2.5A |
Rated Power | 50W | 50W |
Ripple & Noise | 100mVp-p | 100mVp-p |
Voltage Adj. Range | ±10% | ±10% |
Voltage Tolerance | ±1% | ±1% |
Inlet Stability | ±0.5% | ±0.5% |
Load Stability | ±0.5% | ±0.5% |
Setup, Rise, Hold Up Time | 800ms,50ms,10ms/115VAC 300ms,50ms,80ms/230VAC |
|
INPUT |
Voltage Range | 176~264VAC 47~63Hz |
AC Current | 0.7A/115V 0.3A/230V |
Efficiency | 80%/115VAC | 80%/115VAC |
Inrush Current | Cold-start current 15A/115V 30A/230V |
Leakage Current | <0.75mA/240VAC |
| |
PROTECTION |
Over Load | 105%~150% |
Protection type: plusing hiccup shutdown Reset:auto recovery |
|
ENVIRONMENT |
Working Temp., Humidity | -10°C~+60°C(Refer to output derating curve),20%~90%RH |
Storage Temp., Humidity | -20°C~+85°C, 10%~95%RH |
Temp. Coefficient | ±0.03%/°C(0~50°C) |
Vibration | 10~500Hz,2G 10min,/1cycle,Period for 60min,Each axes |
|
SAFETY |
Withstand Voltage | I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC |
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC |
|
STANDARD |
Safety Standard | ApprovedIP67 |
EMC Standard | CLSPR22(EN55022),IEC801-2,3,4,IEC555-2 Verification |
|
OTHERS |
Dimension | 105*32*35mm(L*W*H) / optional |
Weight | 0.17Kg |
2.Input Characteristics :
- Input Voltage:
- Rated Voltage:100-240Vac
- Variation Range:90-264Vac
- Input Frequency:
- Rated Frequency:50/60Hz.
- Variation Frequency:47-63Hz
- Input Current:0.5Arms At any input voltage and rated. DC output rated load.
- Inrush Current: 30 Amps Max. Cold start at 240Vac input, with rated load and 25°C ambient.
- AC Leakage Current: 0.25 mA Max. At 240Vac input.
3. OUTPUT CHARACTERISTICS:
Voltage Min. Load Max. Load Peak Output Power
+12Vdc 0.2A 2A 24W
- 3.2 Combined Load/Line Regulation:
Voltage Min. Load Max. Load Line Regulation Load Regulation
+12Vdc 0.2A 2A ±3% ±5%
Under rated voltage and nominal load,The ripple and noise are as follows when measure with
Max. Bandwidth of 20MHz and Parallel 47uF/0.1uF,crossed connected at testing point.
Voltage Ripple And Noise(Max.)
+12Vdc 150mVp-p
2 second Max. At 115Vac input and output Max. Load.
40mS Max. At 115Vac input and output Max. Load.
5mS Min. At 115Vac input and output Max. Load.
75% Min. At 100Vac input and output Max. Load.
75% Min. At 240Vac input and output Max. Load.
15% Max. When power supply at turn on or turn off.
4. PROTECTION REQUIREMENT:
- 4.1 Short Circuit Protection:
The power supply will be auto recovered when short circuit faults remove.
- 4.2 Over current Protection:
The power supply will be auto recovered when over current faults remove.
- 4.3 Over Voltage Protection
The power supply will not be auto recovered when faults remove 110%-150%.
Products pictures show
Notes of installation and using
1 Three principles of installation and using:
(1) The electricity net voltage should be in the marked range of working voltage,for example , the input voltage of supply power is 170~250V, it should not be connected with the electricity net voltage of 280V.
(2) Don’t use with abnormal load :don’t over loading, ultra light load, the supply power and the load should be matched.
(3) There can not be use for two or more power supply output by parallel connection, otherewise, that can be from high voltage return to low voltage that can be caused the power supply damaged.
A Stabile voltage(see the load features of product 1)
B Stabile current(see the load features of product 2)
(4) To make a installation and environment of good for heat exchange;
A It is strictly prohibited installing in the environment of high temperature
B To make the heat exchange by three kinds of ways of heat transferring
a. Bare in the floating air
b. The space of heat exchange is as large as possible
c. Installed on the metal board of large area ,and contacted well,give out the heat by the metal board
2 Steps of installation:
(1)For good of heat exchange , fix the supply power on the large metal board directly;
(2)The connection should be fastness,the input and output line should not be connected in reverse;the output “ ”connected with the LED“anode”,the output“—”connected with the LED“cathode”;
(3)Make sure the voltage between the connection and supply power is the matchable by multimeter,shut the brake when affirm.
Remark: there are three kinds of wirings on the LED switching supply power of our company: blue and brown, black and red, black and white,the wirings of brown, red , white are the output anode of supply power,the wirings of blue, black , black are the output cathode of supply power;the input wiring is white.The wiring of waterproof with black wiring-protector outside is the input wiring,The wiring with white wiring-protector outside is the output wiring,the output wiring core of white is “anode”, and the black is“cathode”.
The using environment of product and deposited condition
1 Product outdoors can be used :temperature -25~ 40;relative humidity 100%
2 Product indoors can be used:temperature -10 ~ 40;relative humidity ≤ 90%
3 Depostied in:temperature -10~ 60;relative humidity ≤85%
Note: Please operate strictly according to the Product Operating Instructions. Do not directly use the products in harsh environments (such as:PH larger areas or in water use)
Warranty and Our service
1 The product is warranted for two years from the date of leaving factory.
2 The warranty is invalid when one of the cases below happens :
(1)The product went wrong because of not used by the instructions;
(2)The product went wrong because of the user removed the parts inside by himself/herself;
(3)The form of product shattered serious, or transformative;
(4)The date of leaving factory or the gliding number on the product has be scraped off or be altered;
If product quality problems occur within the warranty period, free replacement of the same type of product or repaired bad product.
If you are interested in our products , pls contact me freely! Thank you!