Overview
This apparatus is used for measuring of sulfur in hydrocarbons, such as diesel, naphtha, kerosene, residuals, lubricating base oils, hydraulic oils, jet fuels, crude oils, gasoline (all unleaded), and other distillates. In addition, sulfur in other products, such as M-85 and M-100, may be analyzed using this technique. The applicable concentration range is 0.0150 to 5.00mass% sulfur.
Features
X fluorescence analyzer for sulfur content is a quantitative analyzing instrument used in industries such as petroleum, coal, building materials, metallurgy and mining, for measuring the sulfur content in petroleum products, coal, cement and carbon black.
We use physical analysis method, speedy analysis process, high precision, less human error, low labor intensity, without complicated sample pretreatment and pollution, so it is widely used and replaces chemical analysis method.
Since X fluorescence analyzer for sulfur content produced abroad is expensive, a few Chinese customers use it in production. With the producing of X fluorescence analyzer for sulfur content in China, we believe it will be widely used and replace chemical analysis method step by step. The instrument meets ASTM D4294.
A small X light pipe is used as an excitation source, without isotope radioactive source. With single strength window charge proportional counter and special light path system, the detestability reaches 10pprn. Automatic C/H ratio modification is applicable to various samples; a result can be measured in 15 seconds.
Beautiful and vogue appearance, the instrument has such advantages as integration, continuously measuring standard samples, not contacting and damaging the samples in analyzing, no need of chemical reagent ,cold cathode back light liquid crystal, human-computer dialogue operation, large data storage capacity and strong software function.
Technical parameters
Analyzing range: S analyzing range is adjustable and can be selected with the method of demarcating working curve.
Width of analyzing range: Smax,Smin≤5; taking petroleum as an example: S:0.001~5
Inherent error, analyzing precision: taking petroleum as an example: meet relevant requirements of national standard GB/T17040 and GB/T11140, and also meet relevant requirements of ASTM D4294.
System analysis time: 15×n seconds (n is natural number), recommended value is 60 seconds.
Detectability: 10pprn
Ambient temperature: 5~40
Relative humidity: ≤85 (30)
Power supply voltage: 220V±20V,50Hz
Power consumption of the whole machine: <150W
External dimensions: 560×470×150mm(L×W×H)
Weight: 20kg