Our CELLCHECK intelligent battery monitor is designed special for single cell monitoring. It combines advanced technology with patented hardware for the most thorough stationary battery health analysis in the industry. The module can be pasted on the monitored battery's case directly or mounted an additional rail.
Product Name | Wireless H3G-TA Battery Monitoring System | ||
Battery Type | 2V,6V or 12V battery, capacity less than 3000AH | ||
Used For | Lead Acid, Lithium Battery, Nickel Battery | ||
Monitoring Parameter | Battery voltage, internal resistance, internal temperature, battery string current, voltage, ambient temperature | ||
Multi Communication Protocol Support | CM module has RS485, Ethernet Port, meet MODBUS/RTU, MODBUS/TCP, SNMP protocol and dry contact; it is easy to access third party system. | ||
Power Requirements | Wireless TA module: powered from battery, less than 40mA (2V) or 20mA (6V, 12V) CM module: 85~264VAC,110V~370VDC,15W TC module: DC8~13V,1 W, power from CM. Wireless Convertor: DC8~13V, 2W, power from CM | ||
Communications Interfaces | Wireless TA module:UART, support MODBUS. CM module: RS485, Ethernet Port(10/100M) , meet MODBUS/RTU,MODBUS/TCP and SNMP protocol | ||
Environmental | Operating temperature: -5℃~50℃ Humidity: 5%~90% Atmospheric pressure: 80~110kPa | ||
Application | UPS/EPS/HVDC, Railway, Metro, Airport, Datacenter, Communications, Nuclear Power, Power System, Army, Factory, Government, Battery Manufacturer and Fire &Safety System |
BMS Components
• Continuous 24/7 on-line monitoring
• With 2.4G RF communication technology and reducing half of the wiring, it is more secure and convenient
• One CELLCHECK monitor one cell, including internal resistance, voltage and temperature according ANSI/TIA-942
• Online battery equalization technology
• Serial port with Optical isolation, meet MODBUS protocol, easy to be accessed by UPS controller
• Easy to install without specialized training
All cables including voltage collecting cable, internal testing cable and other conneting cables are all flame retardant lines, and are in compliance with the fire retardant requirements specified in the UL VW-1 and GBT 18380.1 standard.
Packaging & Delivery
Standard Export Carton
Normal Size: 52.3*33.8*19.5
Main Products
Wireless BMS
H3G-TA BMS
H3G-TV BMS
IR Module Sensor
Voltage Module Sensor
Control Module
CLICK HERE!
CLICK HERE!
CLICK HERE!
• IT Enterprise &Data center
• Telecommunications
• Battery supplied applications
• Utilities
• Fire &Safety system
• Remote monitoring
• Base Station
• UPS System
• Nuclear Power Station
• Electric Subsation
• Bank
• Transportation
• Government
Project Cases
User Name Battery Situation Installation Site
At HUASU battery monitoring and management is all we do. We keep on researching it intimately, so you don't have to. Our company was established on year 2003, 4 generations (2V &12V concentrated system, cellcheck system, wireless system) BMS has been developed.
We provide BMS products and related services to the world, such as Schneider, Eaton, Emerson, etc. We also are the qualified supplier of ZTE, Delta and Huawei.
Profession, specialty, refinement and particularity have been the keys to HUASU's success.
Factory Add:No.16, Road 5th of Xiyuan, Xihu Tech-economy Zone, Hangzhou, China
Tel:+86-571-86693075
Fax:+86-571-87968969
Skype: huasu.joanna
Mob/WeChat/WhatsApp:18324428238
Website:http://www.huasucn.com/En/indexEn.html
Our Team
ROHS CE(EMC) UL CE ISO9001
A: Generally, we confirm the battery situation through discharging of the battery. With this handling, we can work on the real capacity but it is very time-consuming. After doing reasearchs, we find the internal resistance of the battery will be increased that due to various causes of capacity decline. If we regularly monitor the internal resistance of the battery and compare it with the initial internal resistance, it will be easy to detect the performance change of the battery and also find out the problem battery.
A: Battery temperature is like human body temperature, when there is a problem with the battery internal temperature will tend to rise, generally like the battery internal part of short circuit, charging voltage is too high will cause temperature rise. Therefore, the problem of battery pack can be detected as early as possible by monitoring the temperature inside the cell.
A: Yes, the control unit can be controlled remotely, and the capacity unit can be controlled by the control unit to discharge the battery. But when discharging, the battery pack needs to be operated manually or other control methods to separate from the power supply system. We have done the whole system including the charger by technology project of remote control, but this method is not promotion, mainly is the present charger stability DC screen is not enough, manufacturers can not guarantee the safety and effectiveness of the remote control function, easily lead to loss of control. At present, the technology of remote discharge products in the market is not mature, as a pilot can, it is not suitable to promote, it is recommended that users do not use this product at present.
A: Yes. We take the method of shallow charge & discharge for the battery to the battery voltage balance section.
A: We have considered various interference conditions during the design , and special EMC is processing on the circuit which can meet the requirements specified in UL and DL / T856 - 2004 , and we have corresponding EMC test reports.
A: Yes. It is very easily access to your third party system. Generally, you only take one or two days to put programs.H3G system comes with a special serial port for the use of third party system, support the MODBUS protocol. The specific access method and communication protocol can be provided by our customer service department.