DOG-2082 Industrial Online Dissolved Oxygen Analyzer
DOG2082 Industrial online Dissolved Oxygen Meter is a kind of highintelligence on line meter that is developed by our company and used for continuous on line monitoring. It can be equipped with DOG208F Polarographic Electrode and can automatically switch from ppb level to ppm level of widerange measurement. This instrument is designed for monitoring the oxygen content in the boiler feed water, condensate water and sewage.
Features
English menu operation: |
It has a complete English display and elegant interface: Liquid crystal display module with high resolution is |
adopted. All the data, status and operation prompts are displayed in English. |
Multi-parameter display: The oxygen concentration value, input current (or output current), temperature values, |
time and status can be displayed on the screen at the same time. concentration value in a 10 x 10mm size. As the |
main display is eye-catching, the displayed values can be seen from a long distance away. Six sub-displays can |
display such information as the input or output current, temperature, status, week, year, day, hour, minute and |
second, so as to adapt to different users’ habits and to conform with different reference times set by the users. |
Technical Indexes
1. Measuring range: 0~100.0ug/L; 0~20.00 mg/L (automatic switching); 0~60% |
Resolution: 0.1ug/L; 0.01 mg/L; 0.1℃ |
2. Intrinsic error of the whole instrument: ug/L: ±l.0%FS; mg/L: ±0.5%FS, temperature: ±0.5℃ |
3. Repeatability of the indication of the whole instrument: ±0.5%FS |
4. Stability of the indication of the whole instrument: ±1.0%FS |
5. Automatic temperature compensation range: 0~60℃, with 25℃ as the reference temperature. |
6. Response time: <60s (98% and 25℃ of the final value) 37℃: 98% of the final value < 20 s |
7. Clock accuracy: ±1 minute/month |
8. Output current error: ≤±l.0%FS |
9. Isolated output: 0-10mA (load resistance <15KΩ); 4-20mA (load resistance <750Ω) |
10. Communication interface: RS485 or 232(optional) |
11. Data storage capacity: l month (1 point/5 minutes) |
12. Saving time of data under a continuous power-failure condition: 10 years |
13. Alarm relay: AC 220V, 3A |
14. Power supply: AC220V±10%, 50±1HZ, 24V DC (optional) |
15. Overall dimension: 146 (length) x 146 (width) x 108 (depth) mm; |
dimension of the hole: 138 x 138mm |
16. Weight: 0.8.kg ( meter) |
17. Working conditions: ambient temperature: 0-60℃; relative humidity <85% |
18. The connection tubes for inlet and outlet water: pipes and hoses |