Industrial Brush
Civilian Brush
Brush Equipment
Brush Raw Materials
Decoration Materials
∨
∧
CX-IPH-1205 Industrial pH meter | |
Measuring range | 0~14.00PH, -l999~+1999mV, 0~99.9ºC |
Resolution | 0.01PH, 0.1mV, 0.1ºC |
Accuracy | ±0.05pH, ±l mV, ±0.3ºC |
Display mode | LED (nixie tube) display, high brightness, eye-catching and highly readable, long viewing distance |
Temperature compensation | automatic: 0 - 99.9 ºC, manual: 0 - 99.9 ºC |
Input impedance | >1012Ω |
Protection grade | IP65 |
Isolated current output | 4~20 mA(load <750 Ω) |
Alarm relay | AC220V, 3A, isolated output of alarming signals |
Communication interface | RS485 or 232(optional) |
Power supply | AC220V, 50Hz ±1Hz, DC24V |
Working conditions | ambient temperature: 0-60ºC; relative humidity ≤90% |
Power-down memory | > 10 years |
Weight and dimension | 96 x 96 x 110 mm; dimension of the hole: 92 x 92mm ,0.8kg |
Installation mode of secondary meter | Drilling type |
Installation mode of electrode | Flow-through/immerged/flanged/pipe-based |
CX-IPH/ORP-0209 Industrial ORP Meter | |
Measuring range | -1999 ~ +1999 mV |
Resolution | 1mV |
Accuracy | 1mV, ± 0.03 C |
Stability | 3mV/24h |
ORP standard solution | 6.86 4.01 |
control range | -1000 ~ +1000 mV |
Automatic Temperature Compensation | 0 ~ 100 C (pH) |
Manual Temperature Compensation | 0 ~ 80 C (pH) |
Signal output | 4 ~ 20 mA output isolation protection |
Communication Interface | RS485 optional |
Control Interface | ON / OFF relay output contacts |
relay hysteresis | freely adjustable |
Current output load | maximum allowable load is 750 |
Signal Input impedance | ≥ 1 × 1012Ω |
Insulation resistance | ≥ 20M |
Signal Input impedance | ≥ 3 × 1011 |
Operating voltage | 220V 22V, 50Hz 0.5Hz |
CX-ICM-1105A Industrial Conductivity Meter | |
Measuring range | (0~20000) μS/cm; temperature: 0~99.9ºC |
Display mode | LED (nixie tube) display, high brightness, striking to the eye and highly readable, long viewing distance |
Resolution | 0.001μS/cm, 0.1ºC |
Electrode constant: | 0.01-20 μS/cm (Electrode K=0.01),0.1~200 μS/cm (Electrode K=0.1) 1.0~2000 μS/cm (Electrode K=1.0) ,10~20000μS/cm (Electrode K=10.0) |
Temperature compensation | Automatic 0-99.9ºC, manual 0-99.9ºC (25ºC Conversion) |
Accuracy | ±l 0%FS, ±0 3ºC |
Isolated current output | 4~20 mA(load <750Ω) |
Alarming relay | AC220V, 3A, isolated output of alarming signals |
Communication interface | Isolated RS485 |
Power supply | AC220V, 50Hz ±1Hz DC24V |
Protection | IP65 |
Working condition | Ambient temperature: 0-60ºC; relative humidity≤90% |
Power-down memory | >10 years |
CX-IDO-1304 Industrial Dissolved Oxygen Meter | |
Measuring range | 0.00~1 9.99mg / L 0.0~199.9% |
Resolution | 0. 01 mg/L 0.01% |
Accuracy | ±1.5%F.S |
Control range | 0.00~1 9.99mg/L 0.0~199.9% |
Temperature compensation | 0~60ºC |
Output signal: | 4-20mA isolated protection output |
Output control mode | On/Off relay output contacts |
Relay load | Maximum 230V5A (AC) ,Maximum l l5V10A (AC) |
Current output load: | Allowable maximum load of 500 ohm. |
On-ground voltage insulation Degree | minimum load of 500VDC |
Operating voltage | 230VACl0%, 50/60Hz |
Dimensions | 96 × 96 × 115mm ,Dimension of the hole: 91 × 91mm |
Weight | 1 kg |
Working conditions | Ambient temperature: 5 - 35 ºC,Air relative humidity: ≤ 80% |
Except for the earth magnetic field, there is no interference of other strong magnetic field around |
CX-RCA-1503 Residual Chlorine Analyzer | |
Measuring range | Optionally 0-2-ppm or 0-20 |
Accuracy | 0.01ppm |
Operating temp | -40-70C |
Display mode | Touch screen LCD |
Signal output | 0/4mA max. load 1k, RS232 |
Control action | Three-way relay ON/OFF |
Set point | 2 points |
Control capacity | 250VAC/7A |
Net weight | 0.5 Kg |
Opening dimension | 92x92x110mm |