YLG-2058 Industrial Online Residual Chlorine Meter
YLG2058 Industrial Online Residual Chlorine Analyzer is a brannew residual chlorine analyzer in our company; It is a
highintelligence online monitor, It is made up of three parts: a secondary instrument and a sensor, a organic glass flow
cell. It can measure residual chlorine, pH and temperature simultaneously. It can be widely used for continuous monitoring
of residual chlorine and pH value of various water quality in power, water plants, hospitals and other industries.
Feateurs:
English Display, English Menu operation: Easy operation, English prompts during the whole operational |
procedure ,convenient and quick. |
Intelligent: It adopts high-precision AD conversion and single chip microcomputer processing technologies and |
can be used for the measurement of the PH values and temperature, automatic temperature compensation and |
self-checking etc function. |
Multi-parameter display: On the same screen, residual chlorine, temperature, pH value, output current, status |
and time are displayed. |
Isolated current output: Optoelectronic isolating technology is adopted. This meter has strong interference |
immunity and the capacity of long-distance transmission. |
High and low alarm function: High and low alarm isolated output, hysteresis can be adjusted |
Technical index:
1. Measuring range |
Residual chlorine: 0-20.00mg/L, Resolution: 0.01mg/L; |
HOCL: 0-10.00mg/L Resolution: 0.01mg/L; |
pH value: 0 - 14.00pH Resolution: 0.01pH; |
Temperature: 0- 99.9 ℃ Resolution: 0.1 ℃ |
2. Accuracy: Residual chlorine: ± 2% or ± 0.035mg / L, take the bigger; |
HOCL: ± 2% or ± 0.035mg / L, take the bigger; |
pH value: ± 0.05Ph |
Temperature: ± 0.5 ℃ (0 ~ 60.0 ℃); |
3. Sample temperature: 0 ~ 60.0 ℃, 0.6MPa; |
4. Sample flow rate: 200 ~250 mL/1min Automatic and Adjustable |
5. Minimum detection limit: 0.01mg / L |
6. Isolated current output: 4~20 mA(load <750Ω) |
7. High and low alarm relays: AC220V, 7A; |
hysteresis 0- 5.00mg / L, arbitrary regulation |
8. RS485 communication interface (optional) |
It can be convenient to computer monitoring and communication |
9. The data storage capacity: 1 month (1 point/5 minutes) |
10. Power Supply: AC220V ± 22V, 50Hz ± 1Hz; DC24V (optional). |
11. Protection grade: IP65 |
12. Overall dimension: 146 (length) x 146 (width) x 108 (depth) mm; |
dimension of the hole: 138 x 138mm |
Note: The wall installation may be ok, please specify when ordering. |
13. Weight: Secondary Instrument: 0.8kg, flow cell with residual chlorine, |
pH electrode weight: 2.5kg; |
14. Working Conditions: ambient temperature: 0 ~ 60 ℃; relative humidity <85%; |
15.Adopt the flow-through installation, inlet and outlet diameter at Φ10. |