AT5006 SPECIFICATIONS:
Frequency range: 0.15--- 1050 MHz
Center frequency display accuracy: ± 100kHz
Marker accuracy: (0.1% span +100kHz)
Resolution of frequency display: 100kHz(4.5 digit LED)
Frequency scans width: 100 kHz/div. To 100MHz/div. In 1-2-5 steps and 0Hz/div. (Zero Scan)
Frequency scan width accuracy: +-10%
Frequency stability: than 150 kHz/ hour
IF Bandwidth (-3dB):
Resolution: 400 kHz and 20 kHz
Video-Filter on: 4 kHz
Sweep rate: 43Hz
Amplitude range: -100dBm to +13 dBm
Screen display range: 80 dB (10dB/div. )
Reference level: -27dBm to +13 dBm (in 10dB steps)
Reference level accuracy: ± DB
Average noise level: -99dBm (20 kHz BW)
Distortion: < -75 dBc: 2nd and 3rd harmonic
3rd order intermod.: -70dBc (two signals > 3MHz apart)
Sensitivity: <5dB above average noise level
Log scale fidelity: ± 2dB (without attn. ) Ref.: 250MHz
Input impedance: 50
Input connector: BNC
Input attenuator: 0 to 40 dB (4*10dB steps)
Input attenuator accuracy: 1dB/10 stepMax.
Input level: +10dBm, ± 25V DC (0dB attenuation) +20dBm, (40dB attenuation)
AT5006 Tracking Generator:
Output frequency: 0.15MHZ to 1050MHZ
Output attenuator accuracy: ± 10dB
Output attenuator: 0 to 40 dB (4*10dB steps)
Frequency response: ± 1.5dB
Output impedance: 50 BNCRadio
Frequency Interference: < 20 dBc