Welcome to brushcapital
Home >Machinery & Industrial Parts » Measurement & Analysis Instruments » Electrical Instruments » Energy Meters
Add to wish list
+ Add a New List
Single Phase Four Phase Electronic Energy Meter
1. Product overview: DTS/DSS three phase electronic watt-hour meter uses imported specific large-scale integrated cir
$0 /Pieces
Stock: 0 Pieces
Quantity:
-+
Min Order: piece
Buy Now
Add To Cart
Send Inquiry
Seller Support:
Trade Assurance — To protect your orders from payment to delivery
Product Details
Transaction Comments
Basic Info
  • Model NO.: HXDZ-70
  • Voltage: 220V
Product Description
1. Product overview: 
DTS/DSS three phase electronic watt-hour meter uses imported specific large-scale integrated circuits,16 bit A/D conversion, digital   multiplier, digital sampling and processing technology and SMT technology. It is design and manufacture according to industrial user's electricity consumption. 
    With three independent units of measurement module, it can measures three-phase forward and reverse active power. Measurement error has excellent long-term stability. With high-quality tantalum capacitors, it has long service life.
It can prevent phase sequence errors, current reversal, different phase of voltage and current, voltage wire disconnection and zero disconnection etc. measurement errors and stealing behavior while wiring. It can measure three-phase active power which the rated frequency is 50HZ.
  The main feature of the product:  Anti-electromagnetic disturbance, low consumption, high precision, wide-range, anti-theft, wide range, long serve life, LCD display. The applicable environmental temperature is -10ºC~50ºC, the relative humidity can not be over 85%.
 
2. Working principle
 
This watt-hour meter adopts three-phase power supply, and it can work normally at any single phase power supply situation.
When this Watt-hour meter is working, voltage and current take samples through sampling circuit, and then send to large scale specific integrated circuit to buffer and magnify, and then 16-bit A/D converter converted into digital signal, an then convert into pulse which is proportional to electric energy through digital multiplier computation. Driving register accumulates power energy and drives pulse indicator, and output pulse for measurement.  
3. Main features
3.1 Three -phase active power measurement. It can work for a long time.
  3.2 It is a instruction for lack of phase
  3.3 Three-phase power supply. The precision of measurement can not be influenced when one or two phases interrupt.
  3.4 Pulse output interface
 
4. Specifications and main technical parameters
4.1 
Specifications and main technical parameters
Model Category The reference voltage Un Rated current In
DSS 156 Three-phase three-wire 3×100V 3×1.5(6)A
DTS 156 Three-phase three -wire 3×57.7/100V 3×1.5(6)A
3×220/380V 3×1.5(6)A
3×5(20)A
3×10(40)A
3×15(60)A
3×20(80)A
3×30(100)A
 
item technical parameter
Precision grade Active power 1.0 grade,2.0grade
Reference voltage(Un) 220V
Reference current(In) 5(40)A,10(60)A,20(100)A
Reference frequency 50Hz
Working voltage range stipulated working voltage range:0.9Un~1.1Un
Expanded working voltage range:0.8Un~1.2Un
Working temperature range stipulated working voltage range:-25ºC ~+55ºC
limited working voltage range:-40ºC ~+70ºC
Storage and transportation limited temperature range:-40ºC ~+70ºC
Power consumption Voltage circuit:≤2W/5VA;current circuit:≤1VA
 
4.2 Basic error (balance load error limit)
Current value Power factor
(COSφ)
error limit (%)
Connect to meter directly Connect to meter through mutual inductor 1 grade 2
grade
0.05IbI<0.1Ib 0.02In≤I<0.05In 1.0 ±1.5 ±2.5
0.1IbI<Imax 0.05In≤I<Imax 1.0 ±1.0 ±2.0
0.1IbI<0.2Ib 0.05In≤I<0.1In 0.5(inductive) ±1.5 ±2.5
0.8(capacitive) ±1.5 -
0.2IbIImax 0.1In≤IImax 0.5(inductive) ±1.0 ±2.0
0.8(capacitive) ±1.0 -
4.5 Range of voltage:
   Normal working voltage:0.9Un-1.1Un
   Limited working voltage:0.8Un-1.15Un
4.6 Power consumption:
   Voltage circuit consumption:<=2Wand 10VA
   Current circuit consumption:<=4.0VA
4.7 Environmental conditions
Normal working temperature: - 10 ºC ~ + 45 ºC
Working limited temperature: -25 ºC ~ + 55 ºC,
Storage and transportation temperature -25 ºC ~ + 70 ºC 
Relative limited humidity: annual average 75% 
4.8 Dimensions: 228mm * 145mm * 72mm.
4.9 Weight: about 1.5kg.
4.10 Safety performance: Products meet the indicators and requirements of GB/T 17215.321 2008
4.11 The meters LCD display 7 bits, 5 bits integers, 2 decimal places, or 6 bits integers, 1 decimal places.
Single Phase Four Phase Electronic Energy Meter
Single Phase Four Phase Electronic Energy Meter
FAQ:
1.Q:How can I get the samples?
  A:If you need some samples to test,please pay for the transportation freight of samples and our samples will be counted on the next order .We send the samples to you only after receipt of your payment.
 
2.Q:How much the transportation freight will be for the samples?
  A:The freight depends on the weight and packing size and your area.
 
3.Q:How can I get your Price list?
  A:Please send us your email or fax and order information,then I can send you the price list.
 
4.Q:Can we have our logo or company name to be printed on your products or the package?
  A:Sure.Your Logo can be puted on our products by sticker.And if you want your logo and company name to be printed on the cartons for the products,you can send us the artwork by email.
 
5.Q:How to order?
  A:Please send us your purchase order by email or fax or you can ask us to send you a proforma invoice for  your order.
 
Thanks for your view,Welcome to visit our
Website:http://cnhxdz.en.made-in-china.com/
Name:Lemon
Tel:+86 13305775392
Other products from this supplier
Back to top
X
Added successfully
You have added this product to the wish list successfully !
X
Added successfully
It has now been moved to the top of the list!
Continue shopping
X
Add a New List
Save
cancel