FEATURES
AVERAGE RATED LED LAMP LIFE OF 50,000 HOURS AT L70 IN TA40C ENVIRONMENTS.
DURABLE ALUMINIUM BODY OPTIONS.
HIGH PERFORMANCE OPTICS WITH IMPROVED ILLUMINATION UNIFORMITY.
UV RESISTANT MOULDED LENS WITH INTEGRAL IP65 SILICONE SEAL.
THREE VERSIONS: NORMAL, SENSOR AND EMERGENCY SYSTEM.
FOUR RATE POWER: 9W, 12W, 18W, 24W. LOW PROFILE IP65, IK10 PROTECTION.
AMBIENT TEMPERATURE, -10°C TO 40°C.
CERTIFICATE CERTIFICATE NO.
----------------------------------------------------------------------------------------------------------------------------------------------------------------------
CE BCTC-2011009787-SZJR
CE BCTC-2011009788-SZJR
IP65 BCTC-2011009789-SZJR
IK10 WDZ1405120341-1
PRODUCTS QUICK INFORMATION VERSION DIM (MM) MASS (KG)
----------------------------------------------------------------------------------------------------------------------------------------------------------------------
NORMAL Φ295×83 1.5
WITH SENSOR Φ295×83 1.8
WITH EMERGENCY Φ295×83 2.2
SPECIFICATION LIST | ALPHARD 9W | ALPHARD 12W | ALPHARD 18W | ALPHARD 24W |
POWER | 9W | 12W | 18W | 24W |
NOMINAL VOLTAGE | AC180-240V | AC180-240V | AC180-240V | AC180-240V |
POWER FACTOR | >0.95 | >0.95 | >0.95 | >0.95 |
PCB CONNECTION | 6SERIES 3PARALLELS | 6SERIES 4PARALLELS | 12SERIES3PARALLELS | 12 SERIES4 PARALLELS |
CHIPS | EPISTAR 5630 | EPISTAR 5630 | EPISTAR 5630 | EPISTAR 5630 |
PCB QUANTITY | 1PCS | 1PCS | 1PCS | 1PCS |
CHIP QUANTITY | 18PCS | 24PCS | 36PCS | 48PCS |
CCT | 3000-6000K | 3000-6000K | 3000-6000K | 3000-6000K |
CRI | >80 | >80 | >80 | >80 |
LUMINOUS FLUX | 857.07LM | 1196.93LM | 1683.82LM | 2235.91LM |
EFFICIENCT | 95.23LM/W | 99.68LM/W | 93.49LM/W | 93.16LM/W |
BEAM ANGLE | 120° | 120° | 120° | 120° |
BODY MATERIAL | ALUMINIUM ADC12 | ALUMINIUM ADC12 | ALUMINIUM ADC12 | ALUMINIUM ADC12 |
DIFFUSER MATERIAL | PC | PC | PC | PC |
IP RATE | IP65 | IP65 | IP65 | IP65 |
AMBIENT TEMPERTURE | -10°C TO 40°C | -10°C TO 40°C | -10°C TO 40°C | -10°C TO 40°C |
STORAGE TEMPERATURE | -10°C TO 40°C | -10°C TO 40°C | -10°C TO 40°C | -10°C TO 40°C |
INNER BOX | 302×302×110 | 302×302×110 | 302×302×110 | 302×302×110 |
OUTER BOX | 625×315×595 | 625×315×595 | 625×315×595 | 625×315×595 |
DIM(MM)
| MICROWAVE SENSOR | | 1. CONNECTION |
POWER SUPPLY | 220-240V | ConNECT N, L - POWER |
POWER FREQUENCY | 50/60HZ | ConNECT N, L’ - LOAD |
HF SYSTEM | 5.8GHZ CW RADAR | |
REACH | 2-10M(RADII.) | 2. SETTING |
LIGHT CONTROL | 0~500LUX | S1, S2 SET SENSITIVITY |
TRANSMISSION POWER | <10MW | S3, S4, S5 SET TIME |
DETECTION ANGLE | 360° | S6, S7, S8 SET THE LUX |
| EMERGENCY SYSTEM | | | |
BETTERY CHARGING | 24HRS | BETTERY SPECIFICATION: Ni-Cd/NI-MH6V 20000MAh HT |
CHARGING CURRENT | 120MA | ENVIRonMENT TEMPERETURE: -10°C TO 55°C |
DISCHARGE CURRENT | 1.15A | HIGHEST SURFACE TEMPERETURE:70°C |
PACKING INFORMATION
1. 302×302×110MM INNER BOX 2. 625×315×595MM OUTER BOX 3. EXPENDED PLASTIC COVER 10 PCS / 1 OUTER BOX
INSTALLATION OR ASSEMBLY INSTRUCTIONS
PLEASE READ THESE INSTALLATION INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR MAINTAINING THIS
EQUIPMENT. THESE INSTRUCTIONS AND LOCAL REGULATIONS(WHERe APPLICABLE), BY AN AUTHORISED AND LICENCED ELECTRICIAN.
importANT – THE PRODUCT MUST BE MAINTAINED AND OPERATED IN ACCORDANCE WITH THE MANUFACTURE’S INSTRUCTIONS, FAILURE TO DO SO MAY DAMAGE THE PRODUCT AND SERVICES. IT IS STRonGLY RECOMMENDED THAT THIS importANT NOTE BE COMMUNICATED TO THE OWNER AND OR OPERATOR OF THE INSTALLATION AT THE TIME OF SITE COMMISSIONING. GOOD PRACTICE DOES NOT RECOMMEND THE 24/7 USE OF PRODUCTS WITHOUT THE APPLICATION OF SUITABLE SWITCH CYCLE INTERVALS. P&Q IS NOT RESPonSIBLE FOR ANY PRODUCT NOT MAINTAINED IN ACCORDANCE WITH THE RECOMMENDED PROCEDURES. ALL PRODUCTS SHOULD BE THOROUGHLY CLEANED ON A REGULAR BASIS TO ENSURE THE OPTICAL PERFORMANCE, TOGETHER WITH THE ELECTRICAL,MECHANICAL AND STRUCTURAL INTEGRITY AS DESIGNED, IS MAINTAINED THROUGHOUT THE SERVICE LIFE OF THE PRODUCT.
“ConSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT CONDUCTOR”
1. PRODUCT SPECIFICATION:
SPECIFICATION LIST | ALPHARD 9W | ALPHARD 12W | ALPHARD 18W | ALPHARD 24W |
POWER | 9W | 12W | 18W | 24W |
NOMINAL VOLTAGE | AC180-240V | AC180-240V | AC180-240V | AC180-240V |
2. STORAGE: PRIOR TO INSTALLATION PRODUCTS ARE TO BE STORED IN COOL AND DRY CONDITIONS.
3. INSTALLATION DRAWINGS
STEP 1: DRILL FOUR 6MM HOLES IN THE CEILING AND THEN PUT THE SETSCREW INTO THE HOLE.
STEP 2: TAKE OFF THE ENCLOSER AND THE REFECTER.
STEP 3: INSTALL THE BASE ON THE CEILING.
STEP 4: INSTALL THE ENCLOSER AND THE REFECTER ON THE BASE.
4. ELECTRICAL FAULT FINDING AND RELACEMENT:
THE SUPPLY MUST BE ISOLATED BEFORE OPENING THE LUMINAIRE. IF ALL ConNECTIONS ARE VERIFIED TO BE CORRECT, THE PRODUCTS ENVIRonMENT MAY BE HAVINg AN ADVERSE EFFECT TO THE COMPONENTS. IF THIS IS THE CASE PLEASE ConTACT YOUR SUPPLIER FOR A MORE SUITABLE REPLACEMENT. ANY FAULT FINDING MUST BE DONE BY A FULLY QUALIFIED ELECTRICIAN AND, IF CARRIED OUT WITH THE LUMINAIRE IN PLACE, UNDER A PERMIT TO WORK. WITH REPLACEMENT OF ANY PART ENSURE THAT WIRES AND ConNECTIONS ARE CHECKED, AND ANY WIRE SLEEVING REFITTED. FOR CEILING LIGHT DESIGN.