I. Product configuration
1.New U-arm main frame 1 set
2.High frequency, high voltage generator device 1 set
3.High performance image processing workstation 1 set
4.24 inch LCD monitor 1 set
5.Electrical box 1 set
6.With light source symmetrical adjustable collimator 1 set
7.17 inch× 17inch Flat Panel Detector 1 set
8.X-ray tube assembly 1 set
II. Main Technical Parameters
Item | Content | Technical Parameters |
High Frequency High Voltage X-Ray Generator | Output Power | 50KW |
Inverter Frequency | 260KHz | |
X-ray source assembly | Anode Type | Rotating |
Nominal tube voltage | 150 kv | |
Radiography voltage | 40-150 kv | |
Radiography current | 10-650mA | |
Radiography mAs | 1mAs – 1000mAs | |
Focal spot | 0.6mm/1.2mm | |
Focus power | 22kW/50kW | |
Anode target angle | 12° | |
Rotary anode speed | 3200rpm | |
Anode thermal capacity | 150 KHU | |
Tube assembly thermal capacity | 900 KJ | |
Tube assembly heat dissipation rate | 180w | |
Collimator Parameters | inherent filtration | 1mm Al |
Additional filtration | 1mm Al+2mmAl | |
Digital Detector | Detector type | A-si Flat Panel |
Scintillating Medium type | Cesium Iodide | |
Field | 17’’×17’’ | |
Pixel Matrix | 3K×3K | |
Pixel Size | 139um | |
Limited spatial resolution | 3.7Lp/mm | |
Grayscale | ≥14 bits | |
DQE | >67 % | |
Shortest imaging time | ≤9s | |
Imaging Workstation | Acquisition Module | Gigabit Ethernet acquisition, enhanced image adaptive process |
Image Processing Module | Tissue Equalization, W/L adjustment, points of interest, a negative phas, noise reduction, smoothing, sharping, single window, double window, four-window, multi-window, move, right-handed 90 degree, 90 degree left handed, horizontal mirror, vertical mirror magnifying glass, image scaling, image restoration, layer information, text annotation, image annotation, length measurement, curve measurement, angle measurement, rectangular length, area of a rectangle, ellipse length, oval area, polygon area, measuring edit measuring deleted. | |
Structural Performance |
U-arm
| Vertical lift distance: ≥1250mm SID adjustment range: 1000mm~1800mm Rotation range of U-arm: -40° ~130° Rotation range of FPD: ≥90° Rotation range of X-ray tube: ≥180° |
III. Characteristics
1. Cesium iodide flat panel detector, adopting advanced manufacturer art, which is of very stable performance.
2. The effective detecting area is of 17’’×17’’, it can satisfy radiography needs of different parts.
3. With workstations international professional and state of the art medical image processing technology, the English operation interface and the DR image processing function.
4. Using a Gigabit Ethernet connection with the DR detector, safe and efficient image acquistion, international Dicom 3.0 standard interface for easy linking into the PACS system, transfer printing.
5. Independent research and development high power high frequency high voltage generator, achieve short exposure time, superior performance, world class.
6. With kV, mAs two button system, kV, mA, s three button system and AEC automatic exposure the three photography mode, can choose to better meet the professional requirements of different users.
7. Human graphical user interface, true color touch LCD screen, digital intelligent control system, 2000 radiography parameters combination make operation is simple and convenient.
8. With multiple automatic protection and fault code hint feature, maintenance more convenient.
9. Independent research and development, production of the new all electric U-arm main frame, a wide range of lifting, rotating, meet standing and supine multi-site photography requirements.
10. Mechanical movement with automatic digital control drive technology, high quality gear motor, stable performance, accurate, reliable.
11. Two mechanical motion controls: close table touch screen, remote control, quick and flexible operation.