PLD8800 Surgical Mobile Digital Radiology Equipment X ray Machine
Remote control operating table (with touch screen control) | 1set |
Imported Canada CPI X-Ray high frequency high voltage generator | 1set |
Remote diagnosis table | 1set |
Toshiba flat panel detector | 1set |
Monitor | 1set |
Toshiba high frequency X-Ray tube | 1set |
Electric multi-leaf collimator | 1set |
High voltage cable | 2 sets |
Digital image system | 1set |
Item | Content | Technical Parameters | |
Power | Voltage | 380V±38V | |
Frequency | 50Hz±1Hz | ||
Capacity | ≥65kVA | ||
Internal Resistance | ≤0.17 | ||
X-ray High Voltage System | Power | 50KW | |
Inverter Frequency | 200KHz | ||
Radiogr aphy | Tube Voltage | 40kV-150kV continuous adjustment | |
Tube Current | 10mA-630mA grade adjustment | ||
mAs | 0.1mAs-630mAs grade adjustment | ||
Time | 1.0~6300ms | ||
Control Interface | LCD button touch screen | ||
Control Handle | One-button operating handle (control spot film, bed body and image system movement) | ||
Digital Control X-ray Tube | Tube Focus; max/min | 1.2mm / 0.6mm | |
Input Power | Big focus 75kW, small focus 27kW | ||
Anode Thermal Capacity | 210KJ | ||
Rotary Anode Speed | 2700rpm | ||
Digital Flat Penal Detector | Active Area | 430(H)×439(V) | |
Pel Matrix: | 3008(H)×3072(V) | ||
Pel Space: | 143μm | ||
Cycle Time: | Less than 6s | ||
Limiting Resolution | 3.5lp/mm typ | ||
A / D Transition: | 14 bit | ||
Energy Range | 40 - 150kVp | ||
Max Dose Entrance (low gain) | 4mR / frame | ||
Data Output | 16 data output Ethernet(1000BASE - T) | ||
Command Control: | Ethernet(1000BASE - T) | ||
Synchronous Exposure Control: | Outside |
Input power: | DC 24V 2A | ||||
Remote Diagnostic Table of Upper Tube | Movement range bed | 90°~0°~-25° | |||
Bed's transverse movement distance | ±110mm | ||||
Longitudinal movement distance of radiography frame and spot film device | ≥720mm | ||||
SID (focus of X-Ray tube to screen distance) | 1100 mm, 1500 mm | ||||
Method to control bed | Remote control, bed-control, soft boot and stay of frequency conversion | ||||
Rotated foot pedal | ±360º | ||||
X-Ray distance | tube | to | screen | 1100~1500 mm two grades electric adjustment | |
Collimator | Electric multi-leaf | ||||
Fixed grid for bed use | Grid density: 215L/INCH, ratio: 10:1, focal distance: 130cm, 18" ×18" |
Main Features:
PLD8800 digital high frequency medical surgical X-Ray equipment has the following features: small occupied area, simple operation, wide suitability, big power, high inverter frequency and high image definition.
photography, gynecological photography (hystero-salpingography) etc various inspections, photography way is DR digital acquisition, it truly achieves no conversion digital.
The highest inverter frequency 200KHz high frequency high voltage generator
Constant direct current high voltage output, it can achieve high quality monochromatic X-Ray and eliminate the harmful effect of soft ray to image thoroughly.
Equipped with high performance and large capacity X-Ray tube Adopt 0.6/1.2mm2 dual focus, 300KHU large capacity and high speed X-Ray tube,it is suitable for long time and high intensity clinical examination.
Imported DR flat panel detector, it does not need any conversion but it can finish digital
photography of each position to achieve real direct digital.
Advanced digital image processing function
Preassembled Windows XP professional operating system and professional image processing software.
Image playback: thumbnails view, sequence replay tools.
Image processing: W/L adjustment, arrows and words etc labels, angle and distance measurement, image scaling, translation, up/down conversion, left/right conversion, rotation, black and white reversal.
Mage storage: image real-time storage, DICOM image send, ashampoo Burning Studio,
derived storage (choose various storage ways Bitmap, JPEG, AVI etc to be used in Word and Power-point office software, it is convenient for the doctors to write diagnostic reports and papers ).
DICOM3.0: can be connected with laser camera to print film and PACS NETWORK.
One combined operating handle is easy to control the movement and spot fil of bed body, image system and rotating foot pedal.
The humanized design of the lateral switch in diagnostic table can control the movement of
the table and image system, also make the operation nearby the station more convenient.
Moving range of the film spot device and image system is more than 720mm. It adopts the "machine move, people do not" control mode to finish a series of inspections from the esophagus to lower abdomen easily.