LXSC-15K~20K, LXSCR-15K~20K
MULTI-JET DRY TYPE VANE WHEEL COLD (HOT) WATER METER
APPLICATION: Measuring the volume of portable water passing through the pipeline.
WORKING CONDITION: Water temperature: ≤40°C or ≤90°C, Water pressure: ≤1.6Mpa
FEATURES: Dry-dial, Multi-jet, Magnetic transmission and magnetic shield, Selected high quality materials for steady and reliable characteristics, Technical data conform to International Standard ISO4064
MAXIMUM PERMISSBLE ERROR
- At low zone is ±5% from minimum flow rate (qmin) to transitional flow rate (qt)(exclusive boundary)
- At high zone is ±2% from transitional flow rate (qt) to overload flow rate (qs)
MAIN TECHNICAL DATA
Type | Size (mm) | Class | qs Max. Flow | qp Nominal Flow | qt Transitional Flow | qmin Min. Flow | Min. reading | Max. reading |
m3/h | l/h | m3 |
LXSC-15K | 15 | B | 3 | 1.5 | 0.12 | 30 | 0.0001 | 99999 |
LXSC-20K | 20 | B | 5 | 2.5 | 0.2 | 50 | 0.0001 | 99999 |
DIMENSIONS AND WEIGHT
Type | size | L Length | B Width | H Height | Connection Thread D | Weight kg |
mm |
LXSC-15K | 15 | 170 | 75 | 100 | G 3/4B | 0.73 |
LXSC-20K | 20 | 200 | 75 | 105 | G 1B | 0.9 |