Basic Info Model NO.: HHSA3350
$0 /Pieces
Stock: 0 Pieces
Quantity:
-+
Min Order: piece
Buy Now
Add To Cart
Send Inquiry
Seller Support:
Trade Assurance — To protect your orders from payment to delivery
Product Details
Transaction Comments
Basic Info
  • Model NO.: HHSA3350
  • Automotive Pressure Monitoring: Pneumatic Gages
  • Specification: RoHS, SGS, Reach
  • Type: Automobile Sensor
  • Trademark: SIMST
  • Origin: Shanghai, China
Product Description
Description
H -Series PRESSURE SENSOR is a ssop-hybrid device including a piezoresistive pressure sensor and a signal conditioning circuit. The H-series Pressure sensor has the features of the small form factor, high reliability and high accuracy. This temperature compensated and calibrated sensor provides an accurate, high level analog output signal that is proportional to applied pressure. The pressure rang of the HHSA3350 sensor cell is 44.8~350 kPa absolute pressure. The supply voltage is 5± 0.5V, the type supply current is 2.0Ma.
H -Series PRESSURE SENSOR can customize the characteristics design according to the requirements of the costumer.

Features
L 1.0% Maximum Error Over 0° To 85° C
L Temperature Compensated Over 40° C to +125° C
L Small size
L High reliability, low drift

APPLICATIONS
L Automotive Pressure Monitoring
L Pneumatic Gages
L Hand-held Meters
Characteristic Symbol Min Typ Max Unit
Pressure Range Pop 44.8 --- 350 kPa
Supply Voltage(1) VS 4.5 5.0 5.5 Vdc
Supply Current IO --- 2 4 mAdc
Minimum Pressure Offset @ VS = 5.0 Volts(3) (0 to 85°C)(2) VOff 0.460 0.500 0.540 Vdc
Full Scale Output @ VS = 5.0 Volts(3) (0 to 85°C) VFSO 4.460 4.500 4.540 Vdc
Full Scale Span @ VS = 5.0 Volts(4) (0 to 85°C) VFSS 3.920 4.000 4.080 Vdc
Accuracy(5) (0 to 85°C) --- --- --- ± 1.0 %VFSS
Sensitivity V/P --- 13.1 --- mV/kPa
Response Time(6) tR --- 1.0  --- mS
Warm-Up Time(7) --- --- 10 --- mS
Offset Stability(8) --- --- ±0.5 --- %VFSS
Power ON Rise Time tpon --- --- 100 mS







Notes:
1. Device is ratiometric within this specified excitation range.
2. Offset (Voff) is defined as the output voltage at the minimum rated pressure.
3. Full Scale Output (VFSO) is defined as the output voltage at the maximum or full rated pressure.
4. Full Scale Span (VFSS) is defined as the algebraic difference between the output voltage at full rated pressure and the output voltage at the minimum rated pressure.
5. Accuracy is the deviation in actual output from nominal output over the entire pressure range and temperature range as a percent of span at 25°C due to all sources of error including the following:
Linearity:Output deviation from a straight line relationship with pressure over the specified pressure range.
Temperature Hysteresis: Output deviation at any temperature within the operating temperature range, after the temperature is cycled to and from the minimum or maximum operating temperature points, with zero differential pressure applied.
Pressure Hysteresis: Output deviation at any pressure within the specified range, when this pressure is cycled to and from the minimum or
maximum rated pressure, at 25°C.
TcSpan: Output deviation over the temperature range of 0 to 85°C, relative to 25°C.
TcOffset: Output deviation with minimum rated pressure applied, over the temperature range of 0 to 85°C, relative to 25°C.
Variation from Nominal: The variation from nominal values, for Offset or Full Scale Span, as a percent of VFSS, at 25°C.
6. Response Time is defined as the time for the incremental change in the output to go from 10% to 90% of its final value when subjected to a specified step change in pressure.
7. Warm-up Time is defined as the time required for the product to meet the specified output voltage after the Pressure has been stabilized.
8. Offset Stability is the product's output deviation when subjected to 1000 hours of Pulsed Pressure, Temperature Cycling with Bias Test.
 
MAXIMUM RATINGS
 
  Table 2 MAXIMUM RATINGS(1)
Rating Symbol Value Unit
Maximum Pressure(P1> PMAX 1400 kPa
Storage Temperature TSTG -40° to+135° °C °C
Operating Temperature TA -40° to+125° °C °C
Output Source Current @ Full Scale Output(2) Io+ 2 mAdc
Output Sink Current @ Minimum Pressure Offset(2) Io- -2 mAdc