1. SPECS FOR THE DESIGN
| MODEL | AR-250-240A | AR-250-208A | AR-250-EU AR-250-AU |
INPUT(DC) | Max Recommended PV Power (Wp) | 285 |
Max DC Open Circuit Voltage (Vdc) | 60 |
Max DC Input Current (Adc) | 12 |
MPPT Tracking Accuracy | >99.5% |
MPPT Tracking Range (Vdc) | 22-55 |
Isc PV (absolute maximum) (Adc) | 14 140 |
Maximum Inverter Backfeed Current to the Array (Adc) | 0 0 |
OUTPUT(AC) | Rated AC Output Power (Wp) | 220 |
Nominal Power Grid Voltage (Vac) | 240 | 208 | 230 |
Allowable Power Grid Voltage (Vac) | 211-264 | 186-228 | configurable |
Allowable Power Grid Frequency (Hz) | 59.3-60.5 | configurable |
THD | <3% (at rated power) / |
Power Factor (cos phi, fixed) | >0.99% |
Current (maximum continuous) (Aac) | 1.2 |
Current (inrush) (Peak and Duration) | 12A, 15us |
Nominal Frequency (Hz) | 60 | 50 |
Maximum Output Fault Current (Aac) | 2.2A peak |
Maximum Output Overcurrent Protection (Aac) | 6.3 |
Maximum Number of Units Per Branch | 15 |
SYSTEM EFFICIENCY | Peak Efficiency | 96.30% | 95.70% | 95.80% |
CEC Efficiency | 95% |
Night Time Tare Loss (Wp) | 0.17 |
PROTECTION FUNCTIONS | Over/Under Voltage Protection | Yes |
Over/Under Frequency Protection | Yes |
Anti-Islanding Protection | Yes |
Over Current Protection | Yes |
Reverse DC Polarity Protection | Yes |
Overload Protection | Yes |
Protection Degree | NEMA-6 / IP-67 I |
Environment Temperature | -40℃——+65℃ |
OTHER PARAMETERS | Environment Humidity | 100%, condensation |
Display | LED LIGHT |
Communications | Power Line |
Dimension (D-W-H mm) | 230*138*35 |
Weight (Kg) | 2.0 |
Environment Category | Indoor and outdoor |
Wet Location | SUITABLE |
Pollution Degree | PD 3 |
Maximum Altitude | 2000 M |
Overvoltage Category | II(PV), III (AC MAINS) |
Product Safety Compliance | UL 1741 CSA C22.2 No. 107.1 | IEC/EN 62109-1 IEC/EN 62109-2 |
Grid Code Compliance* (Refer to the label for the detailed grid code compliance) | IEEE 5047 | VDE-AR-N 4105* VDE V 0126-1-1/A1 G83/2 AS 4777.2 & AS 4777.3 |
| Note: For grid code VDE-AR-N 4105, maximum 3.68kVA PV plant is limited. The grid protection report and setting are readable from the gateway. For grid code G83/2, maximum 16A per phase is limited. The grid protection report and setting are readable from the gateway. |
2. pics for the reference of the products
3.using in the system
Advantage of our micro inverter
How to install the solar grid tie micro inverter ?
Step 1 Install the AC Branch Circuit Junction Box
Step 2 Attach the micro inverter to the Racking or the frame of the panel
Step 3 Connect the inverter Wiring Harnesses
Step 4 Ground the System
Step 5 Complete the connection map and connect the PV Modules
Please check the diagram
4. factory reference.
5. certifcate
6. FAQ
What is solar grid tie micro inverter Microinverter?
A solar micro-inverter, converts direct current (DC) electricity from a single solar panel to alternating current (AC). The electric power from several micro-inverters is combined and fed into an existing electrical grid. Micro-inverters contrast with conventional string or central inverter devices, which are connected to multiple solar panels.
What is the temperature range does the solar grid tie micro inverter micro-inverter can be used?
Temperature range is from ~40°C to +65°C.
What is the advantage of allrun solar grid tie micro inverter ?
More Energy Harvest: Distributed MPPT allows10~25% more energy harvest
Simple: Modularized,single ac cable to the house
Reliability: Longer life time and almost 100% operation hours
Security: No high Voltage, makes safter environments
Inteligent : Monitoring each module
Savings: No dc components and significantly save labor cost
How the solar grid tie micro inverter Microinverter Works?
The allrun Microinverter maximizes energy production from your photovoltaic (PV) array. Each Microinverter is individually connected to one PV module in your array. This unique configuration means that an individual Maximum Peak Power Point Tracker (MPPT) controls each PV module. This ensures that the maximum power available from each PV module is exported to the utility grid regardless of the performance of the other PV modules in the array. That is, although individual PV modules in the array may be affected by shading, soiling, orientation, or PV module mismatch, the ALLRUN Microinverter ensures top performance for its associated PV module. The result is maximum energy production from your PV system