General Features
- Advanced Microprocessor Control
- True Online Double Conversion
- IGBT Rectifier and Inverter
- Real Digital Signal Processor Controlled Transformerless Design
- Active Input Power Factor Correction (≥ 0.99)
- Low Input THDi <%3 Perfect Generator Compatibility
- Low Output THDv <%3 Perfect Energy for your Loads
- Low Total Harmonic Distortion Level
- Excellent Compability with Different Power Factor Loads
- Selectable Input/Output Voltage and Frequency
- Wide Input Voltage Range (160 - 260 VAC)
- High Efficiency Up To 95%
- Ultra High Efficiency with Smart Eco Mode (%98)
- Reliable Parallel / Redundant Operation via Load Synchronization
- Smart Fan Control
- EMI / RFI Filter
- Start on Battery Feature (Cold Start)
- Short Circuit, High/Low Voltage and Overload Protections
- Adjustable Time for Battery Operation
- Battery Deep Discharge Protection
- Standard Static ve Maintenance By-Pass
- Temperature Compensated Battery Charge, Selectable Charge Current
- Advanced Fault Identification, 1000 pcs Alert/Event Memory
- Advanced Communication Options with RS232 / RS485
- 100% Made in TURKEY
- Environment Friendly Design, The Most Silent in Its Class
- Low Installation and Operation Costs
- Easy Maintenance and Service
- 10 Years Spare Part Availability
- 7/24 Technical Service and Customer Services
Optional Features
- Advanced Remote Viewing and Management via SNMP
- 4 Programmable Dry Contacts
- GPRS Modem / CAN BUS Communication Options
- Easy Scalability with Parallelling
- Microprocessor Controlled Smart Battery Management
- Customizable Input/Output Options
Standards
- EN 62040-1 (Safety), EN 62040-2 (EMC)
- TSEK, CE, ISO 9001
Power ( kVA ) | 60 kVA |
INPUT |
Number of Phases | 3 Phases + N + E |
Nominal Voltage / No. of Phases | 380 VAC / 410 VAC / 415 VAC (3 P + N) |
Voltage Range | 176 / 280 Vac. ± % 5 (at Full Load) |
Nominal Frequency | 50 Hz / 60 Hz |
Frequency Range | ± 10% |
Input Power Factor | ≥ 99 |
THDi | < 5% |
OUTPUT |
Nominal Voltage / No. of Phases | 380 VAC / 400 VAC / 415 VAC (3 P + N) |
Voltage Tolerance | ± 1% |
Nominal Frequency | 50 Hz / 60 Hz |
Frequency Tolerance | 50 Hz ± 0,1% / 60 Hz ± 0,1% |
Power Factor | 0,8 |
Crest Factor | 03:01 |
THDv | < 2% (Linear Load) < 4% (Non-Linear Load) |
Waveform | Pure Sine |
Overload Operation | 60 min. at 110% load / 10 min. at 125% load /1 min. at 150% load |
STATIC BY-PASS |
Voltage Range | 175 – 253 VAC ( 3 P + N ) |
Transfer Time | 0 ms. |
Overload Capacity | 150% |
BATTERY |
Voltage / Quantity | 1X62 12V |
Type | Maintenance Free Dry Type |
Charging Current | Selectable |
Temperature Compensated Charge | Microprocessor and Smart Sensor Controlled |
GENERAL |
Technology | On-Line Double Conversion ) |
Control | SPWM Controlled IGBT Rectifier and Inverter |
Efficiency | Up To 95% |
Parallel/Redundant Operation | Optional |
Protection | Overload, Over Temperature, Input/Output Short Circuit |
COMMUNICATION |
Display | 240 x 320 Graphical LCD ( Touch Screen Display ) |
Alert / Event Memory | 1000 pcs. |
Advanced Communication | RS232, 6 Programmable Dry Contacts, GPRS(Optional), SNMP ( Optional ) |
ENVIRONMENT |
Operating Temperature Range | 0 C ~ 40 C |
Relative Humidity | 0% – 95% ( Non-Condensing ) |
Altitute | ≤ 3000 m |
Noise | ≤ 50 dB |
Protection Class | IP20 |
PHYSICAL SPECIFICATION |
Dimensions (W*D*H) | 56*96*110 mm |
Weight | 165 kgs |