AAC (ALC) WALL PANEL:
AAC panel:(Autoclaved Aerated Lightweight Concrete Panel) is also named Autoclaved lightweight Concrete panel which is steel instructure reinforced ,light weight and load bearing.
AAC panels can be used external and interior wall panels and roof panels.
AAC panel is a new kind of building materials that is widely applied to various kinds of building such as industrial construction,civil housing,hospitals,hotels, apartments,schools,supermarkets and so on .
AAC panel can take the place of the traditional concrete and clay brick.
Also the panels can be easily cut, drilled, screwed when installing with gypsum adhesive,U-CARD,hook head bolt and double head bolt due lightweight.
Packing :1x20' FCL can load 22CBM/18000KGS
For more information,welcome to visit our website:www.kingwayaac.com, www.gypsumplate.com. www.kingwaytrading.com.cn.
performance index | ALC test value | standard value |
dry volume density | 512kg/m3 | ±50 |
cubic crushing strength(average value) | ≥4.0Mpa | ≥2.5Mpa |
drying shrinkage | ≤0.3mm/m | ≤0.8mm/m |
thermal coefficient(5%moisture content) | 0.11W/m.k | 0.15W/m.k |
freezing resistance | quality loss | 1.00% | ≤5.0% |
intensity after frozen | ≥3.8Mpa | ≥2.0Mpa |
shock resistance | ≥7.0 times | 3 times |
Single-point Hanging Force | 1200N(100mm),1500N(125mm) | ≥800N |
Bonding Strength Between Rebar and ALC Panel | avg3.5Mpa min 2.8Mpa | ≥0.8Mpa,≥0.5Mpa |
Fire Endurance of ALC Panel | 3.62hours(100mm),≥4hours(125mm) | |
Fire Endurance of 50mm Thick ALC Panel Protected Steel Column | ≥4 hours | 4hours |
Fire Endurance of 50mm Thick ALC Panel Protected Girder | ≥3 hours | 3hours |
R /R Water Softening Coefficient | 0.88% | |
Average Sound Reduction Index (100mm thick ALC panel+ both putty painted sides) | 40.8db | |
Exterior Panel Specification
Specification (mm) | Grade | Interface | Strength grade (MPa) | Min design load (Kn/m2) | Measured dry density (Kg/m3) |
≤3600×600×100 | B05 | T shape | 3.5 | ≥1.2 | 486 |
≤4200×600×125 | B05 | T shape | 3.5 | ≥1.2 | 486 |
≤5200×600×150 | B05 | T shape | 3.5 | ≥1.2 | 486 |
≤6000×600×175 | B05 | T shape | 3.5 | ≥1.2 | 486 |
≤6000×600×200 | B05 | T shape | 3.5 | ≥1.2 | 486 |
Interior Panel Specification
Specification (mm) | Grade | Interface | Strength grade (MPa) | Measured dry density (Kg/m3) |
≤ 3000×600×75 | B05 | T/Flat shape | 3.5 | 486 |
≤ 4000×600×100 | B05 | T/Flat shape | 3.5 | 486 |
≤ 5000×600×125 | B05 | T/Flat shape | 3.5 | 486 |
≤ 6000×600×150 | B05 | T/Flat shape | 3.5 | 486 |
Roof And Floor Panel
Specification (mm) | Grade | Interface | Strength grade (MPa) | Min design load (Kn/m2) | Measured dry density (Kg/m3) |
≤2600×600×100 | B05 | T/L shape | 3.5 | ≥1.4 | 486 |
≤3100×600×125 | B05 | T/L shape | 3.5 | ≥1.4 | 486 |
≤3700×600×150 | B05 | T/L shape | 3.5 | ≥1.4 | 486 |
≤4600×600×175 | B05 | T/L shape | 3.5 | ≥1.4 | 486 |
≤5600×600×200 | B05 | T/L shape | 3.5 | ≥1.4 | 486 |