High Voltage 10kv-15kv Porcelain Expulsion Drop Fuse Cutout
Conditions of UseAmbient temperature: Not higher than +40 º C, not less than -30 º CAltitude: Not exceed 1000m (1000m above can
$0 /Pieces
Stock: 0 Pieces
Quantity:
-+
Min Order: piece
Buy Now
Add To Cart
Send Inquiry
Seller Support:
Trade Assurance — To protect your orders from payment to delivery
Product Details
Transaction Comments
Basic Info
  • Model NO.: fsc-1
  • Type: Current Fuse
  • Shape: Circle
  • Fusing Device: Fuse Link
  • Certificate: ISO, Kema, CNAS
  • Application: Distribution Line
  • Rated Current: 100A, 200A
  • OEM Service: Provided
  • Function: Over-Current Protection
  • Transport Package: Carton, Pallet
  • Origin: China
  • Breaking Capacity: High
  • Usaga: High Voltage
  • Fusing Speed: K, T, H
  • Standard: IEC60282-2, ANSI C37.41, ANSI C37.42
  • Accessories: NEMA Bracket, Fuse Link, Arc Shortening Rod
  • Rated Voltage: 10-15kv
  • Sample: Provided
  • Fuse Base Material: Fuse Base Material
  • Trademark: FUERTE
  • Specification: 38.5*34.5*10.5
  • HS Code: 85351000
Product Description
Conditions of Use
Ambient temperature: Not higher than +40 º C, not less than -30 º C
Altitude: Not exceed 1000m (1000m above can be corrected GB311.1-1997)
Power frequency: 50 ± 2Hz
Earthquake intensity: 7 degrees below
Maximum wind speed: 35m/s
PRODUCT DESCRIPTION
FSC-1 medium voltage overhead line overload protection porcelain dropout fuse cut out
Technical Specifications
Type Rated Voltage
(KV)
Rated Current
(A)
Breaking Current
(A)
Impulse Voltage
(BIL)
Power-frequency withstand voltage 
(KV)
Leakage Distance
(MM)
FSC-1 15 100 10000 110 40 220
15 200 12000 110 40 220
Accessories Nema Bracket,fuse link,arc-shortening rod (Can be provided as customer's request.)
Main material Wet process porcelain,copper,brass,stainless steel,hot dip galvanized steel

High Voltage 10kv-15kv Porcelain Expulsion Drop Fuse Cutout

High Voltage 10kv-15kv Porcelain Expulsion Drop Fuse Cutout 
High Voltage 10kv-15kv Porcelain Expulsion Drop Fuse Cutout
High Voltage 10kv-15kv Porcelain Expulsion Drop Fuse Cutout

 

General
Drop-out fuse and pull the load drop-out fuse is outdoor high-voltage protection of electrical. It is installed in high-voltage side of the distribution transformer or the Support Link of the distribution line as Transformers and lines short circuit, overload protection, and open, co-load current. Drop-out fuse is made by the insulating bracket and fuse tubes, static contact is installed at both ends of the insulation bracket, Moving contact installed on both ends of fuse tube, Fuse tube is composed by inner arc tube and outer phenolic paper tube or epoxy glass cloth tube. Pull load drop-out fuse can enhance flexibility auxiliary contacts and arc chute for open, co-load current. 
When drop-out fuse in the normal operation, the fuse tube with fuse tension to form the closed position. When the system fails, the fault current blown fuse quickly, And form of arc, arc tube by the electric arc burning, Decompose large amounts of gas, formed a high pressure in the tube, and formed vertical wind along the pipeline, The arc was quickly stretch and elongated. After fuse blows, the moving contact lose tension and turned out, locking mechanism, release fuse tube, fuse tube drop, formed breaking Position. When pull the load, use insulating rod to pull the moving contact. At this point, the moving and the static contact is still contact. Continued pull the contact with the insulating rod, the auxiliary contacts are separated. The arc appear between the auxiliary contacts, and was stretch in the hood slit, the arc cover has gas, when the current is 0, the arc goes out. 

Use and Standards
This product is used in 10 ~ 35KV distribution lines branching lines and distribution transformers primary side, For overload and short circuit protection Separation and Combination the rated load current. 
The product model by JB/T8321-1996Method of type AC high-voltage fuses prepared. Product parameters made by GB15166.3-1994 high voltage fuses Expulsion fusesstandards. The standards are not clearly defined the important parameters and configuration, According to JB/DQ2139-198610 ~ 35KV outdoor high voltage drop fuse interim technology requires correction. 

High Voltage 10kv-15kv Porcelain Expulsion Drop Fuse Cutout
High Voltage 10kv-15kv Porcelain Expulsion Drop Fuse Cutout


 

 

Other products from this supplier
Back to top
X
Added successfully
You have added this product to the wish list successfully !
X
Added successfully
It has now been moved to the top of the list!
Continue shopping
X
Add a New List
Save
cancel