Welcome to brushcapital
Home >Health & Beauty » Health & Medical » General Assay & Diagnostic Apparatuses
Add to wish list
+ Add a New List
High-Quality Disposable Measure Cardiovascular Disease Electrocardiograph/ECG Machine
OverviewQuick DetailsType:Pathological Analysis Equipments, Electronic ECGPlace of Origin:Guangdong, China (Mainland)Model Number:ECG-3301Th
$400 /Set
Stock: 1000000 Sets
Quantity:
-+
Min Order: piece
Buy Now
Add To Cart
Send Inquiry
Seller Support:
Trade Assurance — To protect your orders from payment to delivery
Product Details
Transaction Comments
Overview
Quick Details
Type:
Pathological Analysis Equipments, Electronic ECG
Place of Origin:
Guangdong, China (Mainland)
Model Number:
ECG-3301
Three working modes:
Munual, Automatic, Arrythmia Analysis
Product:
ECG / EKG / Electrocardiograph
Category:
Medical equipment
Properties:
Diagnostic Apparatus
Channel format:
Single channel recording
Advantage:
Automatic interpretation
Lead:
12 leads
Certificated:
CE
Package:
1pc/box, 4pcs/carton
Packaging & Delivery
Packaging Details
1 set per box, 4 sets per carton
Delivery Time
10 days

Specifications

ECG Machine
1.For cardiovascular disease test
2.Use for family medical health care
3.Portable ECG machine

High-Quality Disposable Auto Handheld Electrocardiograph

 

Portable ECG manager with the development of electronic, communicative and software technique, It has significant meaning for the early-stage prediction for cardiovascular disease and family medical health care,  It has great promotion on size, power consumption, and data storage and data transmision, property and quality, It is great influence on the life security of the patients.

 

ECG manager use analog low-pass and analog high-pass analog filter just like components band-pass to filter out signal interference, while the use of active notch filter frequency of 50Hz can further filt out interference, getting a more pure ECG signal. And then through the implementation of A/D conversion, single-chip processing system, the final test results will be displayed by LCD. The ECG analyzer has good characteristics such as low-power, portable and real-time and so on.

 

Feature:

1. For the cardiovascular disease testing

2. Use for family medical health care

3. Portable and automatic analysis

4. Precise dataflow analysis and persistent record

 

Feature:

1. For the cardiovascular disease testing

2. Use for family medical health care

3. Portable and automatic analysis

4. Precise dataflow analysis and persistent record

 

Features: 3301,3301G (single channel)
1. Compact in size, easy and direct operation, portable
2. Three working modes: Munual, Automatic, Arrythmia Analysis
3. 50mm, single channel format recording
4. Automatic interpretation
5. 20x2 character LCD for 3301
6. 320x240 graphic 3.8 inch LCD for 3301G
7. Adapt to 110-230V, 50/60Hz power supply
8. Built-in rechargeable Li-MH battery
9. Last print review
10. Real-time ECG waveform, 20 patient save and replay for 2201G
11. RS232/USB interface (only for ECG-2201G)
12. ECG software is optional
13. Memory for 20 ECG
14. Safety standards: Class I, type CF.

 

Specification:
Lead: Standard 12 leads
Lead acquisition: 12bit/1000Hz(synchronously 12 leads)
Work mode: MAN, AUTO, ANALYSIS Modes
Filter:
AC Filter:50Hz/60Hz, EMG Filter: 25Hz/45Hz, Auti-Drift Filter: 0.15Hz (Adaptive)
CMMR:100dB(with AC FILTER)
Input circuit: Floating; Protection circuit against Defibrillator effect
Input Impedance:50MΩ
Input circuit current:0.05μA
Patient current leakage: <10μA
Calibrating voltage: 1mV±2%
Voltage tolerance: ±500mV
Time constant: 3.2s
Frequency response: 0.05~160Hz(-3dp)
Noise level: <15u Vp-p
Inter-channel Interference: 0.5mm
Sensitivity: 5,10,20mm/mV
Recording mode: Default Man. Mode is 1ch format, Default Auto. Mode is 1ch+ format
Paper speed: 25,50mm/s(±3%)
Paper: 50mm Roll/Z-Fold
Communication: RS232/USB port(only for ECG-2201G)
Power supply: AC 110-230V(±10%),50/60Hz(±1Hz), 30VA
DC Built-in rechargeable battery, 12V(1500mAh)
Dimension/Weight: 285x265x72mm/2.8kg

 

 

Product Details: Structure & Function

 

1. Front Panel and LCD

 

 High-Quality Disposable Measure Cardiovascular Disease Electrocardiograph/ECG Machine

 

 High-Quality Disposable Measure Cardiovascular Disease Electrocardiograph/ECG Machine

 

 

2. Control Keypad Panel

 

High-Quality Disposable Measure Cardiovascular Disease Electrocardiograph/ECG Machine 

The function of Keypad as following : High-Quality Disposable Measure Cardiovascular Disease Electrocardiograph/ECG Machine 

 

 

3. Lateral Panel

 

High-Quality Disposable Measure Cardiovascular Disease Electrocardiograph/ECG Machine 

Patient Cable Interface

High-Quality Disposable Measure Cardiovascular Disease Electrocardiograph/ECG Machine

 

Analog I/O and RS232 Interface: Used for
* View and Print analog External Input In [MAN] Mode [TEST] lead.
* Export the Rhythm Lead of the [BASIC] menu to Analog External Output.
* Low speed ECG communication with Personal Computer(Need optional ECG software).
CAUTION: Setting [External Input] of [ADVANCE] menu to [YES] for Analog External Input.

High-Quality Disposable Measure Cardiovascular Disease Electrocardiograph/ECG Machine

 

USB and LAN Interface: Used for
* High Speed Real-Time or Long-Time ECG recording based on Personal Computer System(This
need a optional ECG software, Please refer to the ECG Workstation Software Operation Manual
for more information).

 

 

4. BottomPanel

 

High-Quality Disposable Measure Cardiovascular Disease Electrocardiograph/ECG Machine

 

 

5. Connecting Electrodes(as following)

The identifier and color code of electrodes used comply with IEC requirements. In order to avoid
incorrect connections, the electrode identifier and color code are specified in below Table. The
equivalent code of American standard is given too.

High-Quality Disposable Measure Cardiovascular Disease Electrocardiograph/ECG Machine

The Limb/Chest electrode should be placed on body surface shown as following:

V1 : Fourth inter-costal space at right border of sternum.
V2 : Fourth inter-costal space at left border of sternum.
V3 : Fifth rib between V2 and V4.
V4 : Fifth inter-costal space at left mid-clavicular line.
V5 : Left anterior axillary line at the horizontal lever of V4.
V6 : Left anterior mid-axillary line at the horizontal lever of V4.

 

High-Quality Disposable Measure Cardiovascular Disease Electrocardiograph/ECG Machine

NOTE : Tangling of electrodes or overlap from one place to another of ECG creamis not allowed.

 

 

 6. Accessories

High-Quality Disposable Measure Cardiovascular Disease Electrocardiograph/ECG Machine

High-Quality Disposable Measure Cardiovascular Disease Electrocardiograph/ECG Machine

 

 

 

Factory:

1. Quality first spirit

2. Professional service team

3. Convenient transport

4. Certificate: Medical CE, CMD, CCC

 

 

 

Chongqing Joywell Trade Co.,Ltd.  has been in Chongqing China in 1999, It has a professional team to engage at international business.

 

Qulity spirit, wonderful service and team work are always the first. Through develop more than 10 years, we have lifted up a new stage and established a wide customer group which from United States, United Kingdom, Cannada, Germany, Japan, South Korea, Iran, New Zealand, Qatar, Irealand, Spain, Netherland, Chile, etc.

 

The team cooperation open up and share innovation.

AIM: Employee's success is the success of the company.

VALUE: Intergrity first, customer first, cooperation sharing, happy passion, refince on active, thanksgiving growth.

MISSION: Let customer satisfaction, let the Joywell products are well-known in the world.

VISION: To meet the challenge, success!

 

We would like cooperate with clients from all over the world.

 

 

 

Other products from this supplier
Back to top
X
Added successfully
You have added this product to the wish list successfully !
X
Added successfully
It has now been moved to the top of the list!
Continue shopping
X
Add a New List
Save
cancel