controlling Characteristics | Control mode | V/F control Vector control without PG | |
Output range of frequency | 0.01~600.0Hz | ||
Frequency setting analyzing degree | 0.01Hz | ||
Output frequency analyzing degree | 0.01Hz | ||
PWM load wave frequency | Available to modulate from 0.5 to 15 kHz | ||
Torque increase | Vector control without PG:0.5Hz/150%(SVC) | ||
Jog frequency | 3 points can be set from 0.01 to 600.0Hz | ||
Acceleration/deceleration time | 0.01 to 3600.0 seconds. (Acceleration /deceleration time in 2 phases can be set separately) | ||
Stall Prevention Level | According to the load characteristics of motor, it' s available to be set as 100% to 200% of the rated current of the drive | ||
DC braking | braking 0 to 150% of the rated current. Starting time 0.0 to-50.0 sec, Stopping time 0.0-50.0 sec | ||
Braking torque | 20% (125% shall be available if connected with purchase braking resistor externally) (1-25HP braking resistor is installed inside;30HP can connect externally with brake unit module) | ||
speed regulation ratio | Vector control without PG:1:100 | ||
Operation characteristics | Frequency setting signal | Digital Operator | Set by UP and DOWN |
External terminals | 0-10VDC, 4-20mADC, Series Communication Board (RS-485) | ||
Operation Signal | Digital Operator | Available to be operated by RUN, STOP and JOG keys. | |
External terminals | 2 wire styles (Fwd/Stop, Rev/Stop, Run/Stop and Fed/Rev) /3 wire operation, JOG running, Serial Communication Board(RS-485) | ||
Intelligent Input Terminal | Speed shift can be preset in 8th phase ;the first/second acceleration and deceleration time shift: prohibition of acceleration and deceleration ;external interrupt ;inching operation ;increasing/decreasing frequency setting terminal | ||
Intelligent Output Terminal | During running, frequency arrival and output , , non-zero count agreement output, over torque output, external interrupt reference. Low voltage detection, operation mode reference, fault output and external fault interruption. | ||
Analog signal output | Correspond to actual output frequency or output current. | ||
Fault signal contact | For ac drive failure ,the contact is "on"(a relay with "c" contactor a open-collector output | ||
Built-in Function | Upper and lower limits setting of output frequency, instantaneous restart for abnormal malfunction, automatic voltage output regulation ,anomaly records ,parameter hold ,parameters reset to the factory defaults ,prohibition of reversion ,over-current stall prevention ,over-voltage stall prevention ,electronic thermal relay | ||
Protection Function | Protection of inverter unit phase ,accelerated over-current, decelerated over-current, constant-speed over-voltage, bus under-voltage failure, motor overload ,inverter overload ,open -phase at output side (75KW+models ),rectification modules overheating, overheating fault of inverter module ,external fault ,communication fault ,current detection fault ,motor self-learning fault ,EEPROM operational fault ,PID feedback disconnection fault, braking unit fault | ||
Digital operator | Consisting of 8 functional keys, 7 step LED in 5 digits; 5 status LED indicators. Available to set frequency, display actual output frequency, output current, self-determined unit parameter overview of users, modify settings and for parameter locking, fault displaying. Available to perform running, stop, reset, fwd/rev run and jog run. | ||
Environment | Operational Environment temperature | -10° C to +50° C (+40° C ~ +50° C available when the dust cover is removed) | |
Storing temperature | -20° C to + 60° C | ||
Installation height | Lower than 1000m, without corrosive gas, fluid and dust. | ||
Vibration | Below 20Hz 9.80665m/s² (1g), 20~50 Hz 5.88m/s² (0.6g) | ||
Protection degrees | IP20 (Determined by the installation environment of the end-users.) |