For industrial equipment / PFC function DRP-480-24 Din Rail switching power supply high quality 480W 24V 20A power supply
480W Single Output Industrial DIN Rail Power Supply DRP-480 series
Features:
Universal AC input/ full range
Built-in active PFC function
Protections: Short circuit/ Over load/ Over voltage/ Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
LED indicator for power on
100% full load burn-in test
Fixed switching frequency at 100KHz
2 years warranty
SPECIFICATIONS | ||
OUTPUT |
| |
Model | DRP-480-24 | DRP-480-48 |
DC Voltage | 24V | 48V |
Rated Current | 20A | 10A |
Current Range | 0-20A | 0-10A |
Rated Power | 480W | 480W |
Ripple & Noise | 80mVp-p | 150mVp-p |
Voltage Adj. Range | 24-28V | 48-53V |
Voltage Tolerance | ±1% | ±1% |
Setup, Rise Time | 800ms,40ms/230VAC 800ms,40ms/115VAC at full load | |
Hold Up Time | 24ms/230VAC 24ms/115VAC at full load | |
|
| |
INPUT |
| |
Voltage Range | 85~264VAC 47~63Hz; 120~370VDC | |
AC Current | 2.8A/115V 1.4A/230V | |
Efficiency | 84% | 85% |
Inrush Current | Cold start 27A/115V 45A/230V | |
Leakage Current | <3.5mA/240VAC | |
|
| |
PROTECTION |
| |
Over Load | 105%~150% | |
Protection type: Constant current limiting, recovers automatically after fault condition is removed | ||
Over Voltage | 30-36V | 54-60V |
Protection type: Shut down o/p voltage, re-power on to recover | ||
Over Temp. | 100℃±5℃(TSW1) | |
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down | ||
|
| |
ENVIRONMENT |
| |
Working Temp., Humidity | -10℃~+70℃; 20%~90%RH | |
Storage Temp., Humidity | -20℃~+85℃; 10%~95%RH | |
Vibration | 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes | |
|
| |
SAFETY |
| |
Withstand Voltage | I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | |
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC | |
|
| |
STANDARD |
| |
Safety Standard | Design refer to UL508,UL60950-1, TUV EN60950-1 | |
EMC Standard | EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2(EN50082-2) | |
|
| |
OTHERS |
| |
Dimension | 227*125.2*100mm(L*W*H) | |
Weight | 2.5Kg | |
Packing | 12pcs/carton | |
|
| |
NOTE |
| |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. |