Product Description |
FST800-3051HP Firstrate Final Manufacturer low cost differential pressure transmitter is used the Monocrystalline silicon sensor chip which imported from Germany , floating structure design, with super Overvoltage performance and excellent stability. The product can measure differential pressure accurately and converts it into a 4-20mA signal output. The product can be operated by a three-button local operation or a universal terminal and configuration software remotely. Products are widely used in petroleum, chemical, Electricity, pulp, paper, city gas, steel, machinery, shipbuilding and other industrial fields. |
Product Features |
♦ High accuracy: Differential pressure (flow) Transmitter's measurement range is within 0.5 ~ 500kPa , can be carried out with high accuracy measurement. Standard calibration range accuracy: ± 0.075%, plus or minus zero migration, No need for linear adjustment. ♦ Excellent environmental adaptability: Intelligent static pressure compensation and temperature compensation to protect the transmitter from temperature, static pressure and over-pressure effects, and control the field measurement error to be minimum value. ♦ Operability and convenience, 5 digit LCD display with backlight, Various units available (Pa, Kpa, Mpa, bar, mbar,%, psi, mmH2O), Field button function operation, with a variety of anti-corrosion materials, a comprehensive self-diagnostic function ♦ Smart HART fieldbus protocol |
Product Specifications |
Measured fluid | liquid, gas, steam |
Measuring range | kpa | mbar | mmH2O |
HP1 | 0.5~10 -10~10 | 5~100 -100~100 | 50~1000 -1000~1000 |
HP2 | 1~20 -20~20 | 10~200 -200~200 | 100~2000 -2000~2000 |
HP3 | 1~40 -40~40 | 10~400 -400~400 | 100~4000 -4000~4000 |
HP4 | 1~100 -100~100 | 10~1000 -1000~1000 | 100~10000 -10000~10000 |
HP5 | 2~200 -200~200 | 20~2000 -2000~2000 | 200~20000 -20000~20000 |
HP6 | 5~500 -500~500 | 50~5000 -5000~5000 | 500~50000 -50000~50000 |
Note: | Work pressure (Membrane box code and wetted material code,please see the selection table) |
Membrane box | wetted parts materials | Work pressure (unilateral + bilateral) |
HP1,HP2,HP3,HP4,HP5,HP6 | 01,02,03,04,05,06 | 25MPa |
Allowable load resistance 0~600Ω | 0 ~ 600Ω (at DC 24V) Note: |
Noted | At least 250Ω load resistance is required to communicate with the handheld communicator |
Power supply | 24VDC(10.5VDC~45VDC), Intrinsically safe:10.5~26VDC |
Signal Output | 4~20mA DC+HART protocol |
Communication line condition |
Line length | 2Km(0.75~1.25mm2) Controller cable, if more than 1km ,use twisted pair cable |
Load Resistance | 250 ~ 600Ω (DC 24V, including cable resistance) |
Load capacitance | below 0.55mF |
Load inductance | below 3.3mHmF |
Power line interval | above 15cm (to avoid parallel wiring) |
Saturation current limit | maximum: 20.8mA, minimum: 3.8mA |
Alarm current limit | maximum: 22.8mA, minimum: 3.6mA (mode can be set) |
adjustment function | Zero, full-scale point can be adjusted by the first three keys in the display. It can be also adjusted in the live site or be adjusted remotely by the configuration software. |
zero shift | Shift from a maximum range of -20% to + 20% |
Output | Iinear output Square root output (can be remotely adjusted by configuration software) |
Ambient temperature | -40~+85°C(when fully fill in Fluorine oil -10~+60°C) |
storage temperature | -40~+90°C (When filling fluorine oil,-10~+60°C) |
weatherability | DIN40040GPC |
EMC Applicable standards | EN1326-1:2006 |
Performance Specifications |
Specifications of voltage excitation(10VDC 25°C) |
Accuracy | range | reference accuracy | |
| HP1,HP2,HP3,HP4,HP5,HP6 | TD 1:1 | =±0.075% |
| TD-range ratio | Td > 1:1 | =±(0.008×TD+0.075)% |
| | | |
Square-root output accuracy | Output | Accuracy |
| ≥50% | the same as references accuracy |
| 50 -Drop points | Reference accuracy*50 Square root ouput |
Ambient temperature effects | Total amount of effect/28°C(50º F) | effect |
| HP1,HP2,HP3 | ±[0.07% range +0.015%maximum range ] |
| HP4,HP5,HP6 | ±[0.07% range+0.03% maximum range] |
Static pressure effect | HP1,HP2,HP3,HP4,HP5,HP6 | ±[0.1% range +0.028% maximum range ]/6.9MPa |
over pressure effect | ±0.05% maximum range /16MPa |
stability | maximum range/year |
power supply effect | ±0.005% /1V |
Impact of installation location | the diaphragm surface which is parallel to the mounting position changes will not cause zero drift, if the mounting position and diaphragm surface changes over 90 °C |
response time | 90ms |
Damping | The time constant can be adjusted within 0 ~ 99.9 seconds |
Filter constant | Can be adjusted within 0 ~ 160uA |
Self-stabilizing coefficient | Can be adjusted within 0 ~ 2% |
| |
Structure Material |
Wetted part material | showed in selection model table |
| Detection parts |
Material code | Isolation diaphragm | Install the splint |
01 | SUS316L | SUS316 |
02 | Hastelloy C-276 | SUS316 |
03 | Tantalum | SUS316 |
04 | SUS316L gold-plating | SUS316 |
05 | Hastelloy C-276 | Hastelloy C |
Contact liquid seal ring | Fluorine rubber, NBR (optional) |
transmitter housing | Low copper aluminum die casting + polyurethane coating |
transmitter housing cover | Low copper aluminum die casting + polyurethane coating |
IP grade | IP67 |
Inscription card | SUS304 |
Filling oil | Silicone oil, fluorine oil (optional) |
Dimension | according to the diagram |
Gross weight | About 2.2 ~ 2.7 kg (body) |
Cable entry | G1/2,1/2-14NPT,M20*1.5 |
Outer end | M3 Screw |
Process connection | 1/4-18NPT or Rc1/4 |
installation method | Use a U-bolt on a 50mm (2-inch) pipe or install on a wall (based on model specifications) |