Outline evaporative cooling system
1. The process of evaporation is a process in which water absorbs heat and transfer from liquid state to gaseous state. Our product exploit this phenomenon to realize heat exchange between indoor and outdoor air.
2. Indoor and outdoor temperature & humidity sensors collect data, when the temperature difference between inside and outside accord with the set value, Evaporative cooling & ventilation system begins to work.
3. When the outdoor temperature higher than the set value, Evaporative cooling ventilator will stop working, then the controller will start the ICT room air condition to make ensure that the room internal temperature meet the requirements.
Technical Parameters
No. | Model | Rated airflow (m3/h) | Rated power (W) | cooling capacity (kW) | Energy efficiency ratio |
1 | SLXF-03 | 3000 | 450 | 9.10 | 20.1 |
2 | SLXF-05 | 5000 | 750 | 15.08 | 20.1 |
3 | SLXF-10 | 10000 | 1360 | 29.38 | 21.6 |
4 | SLXF-15 | 15000 | 2000 | 42.42 | 21.2 |
5 | SLXF-18 | 18000 | 2400 | 48.96 | 20.4 |
Features of functions
1. Enclosure is made of high-quality high-strength, high durability engineering plastics , with anti-UV, anti-aging, long life and other advantages, and load bearing capacity, not easily deformed , which is capable of more than a decade's use .
2. Built- reel filters , external dust filter , removable, easy to wash , filtration class H10.
3. High-density green wet-film evaporation, high evaporation efficiency, better cooling effect .
4. Low noise centrifugal fan, system noise less than 65dBA.
5. The embedded draning system , prevent water to be sucked-in because of aging water pipes , ruptured water pipes
6. Using flooding protection, automatic cleaning, dust detection , fire alarm , frequency control, sensor backup design .
Technical advantages
No. | Comparison project | Hop Evaporation cooling ventilation | Other companies | Remark |
1 | Using filters. | Automatically detect filtration cotton to be clogged or not and replace clogged cotton | Artificially replace the flat filter . | Automatically detect filtration cotton is clogged or not , automatically replacement it if filtration cotton clogged |
2 | Wet-film number | 3-4 side wet-film, evaporation area has expanded 3-4 times | One side wet-film, evaporation area is small | Evaporated air intake efficiency improve to 50 % to 75% . |
4 | Using fan | Centrifugal fan, high wind pressure , maximum wind speed reaches 25m / s | Axial fan ,low air pressure, maximum wind speed does not exceed 15m / s | High air pressure ,send air to long distance . |
5 | Quiet design | Quiet isolation unique design, indoor noise below 65dB, outdoor noise less than 70dB | Indoor noise below 70dB, outdoor noise less than 75dB | When the room is in a residential area or office area, should prevent noise nuisance. |
6 | Water way design | The embedded water distribution system , prevent water to be sucked in room because of aging water pipes , ruptured water pipes | Use exposed pipes, pipe joints or pipes burst after aging , water droplets are inhaled room | prevent water to be sucked in room because of aging water pipes , ruptured water pipes |
7 | Automatic cleaning function | Automatic cleaning interval can be set according to the local water and air pollution | Can not be based on water and air pollution flexible settings | Can be timed to discharge dirty water . |
8 | Air conditioning linkage | When the outdoor temperature higher than the set value, Evaporation cooling ventilation to stop working, then the controller will start the engine room air conditioner | Simultaneous activation of multiple air conditioners | Room temperature conditions can be flexibly adjusted according to the using |
9 | variable speed motor | According indoor’s and indoor’s temperature , fan speed through frequency conversion adjust the speed , reducing fan consumption | No frequency control section | Can do fine energy saving, avoid unnecessary energy consumption |
10 | Backup temperature and humidity sensor | 100 square meters below room temperature and humidity sensor detection point of not less than three ( near, middle and far ) , 100 square meters above room temperature and humidity sensor detects the point of not less than five ( installation position refer to the installation specification ).The controller uses the average value of sensor’s data | Only a maximum of two indoor temperature and humidity sensor | If any sensor fails, the system will automatically identify and remove wrong sensor, and then averaging the remaining sensor’s data |
Some Pictures
Our official partners around the word:
Certification:
Packing terms:
Using high quality waterproof to pack the air conditioner first, then using melaleuca kraft packing, final using thick laminates.
Leading time:
Usually about 20 days. The exact lead time need to be confirmed according to the quantity of order.
Per conveyance:
Pointed delivery-agent. DHL,UPS or Fedex by your account will be all ok. Also we can hunt for the delivery agent with the best price in China if you need us to do for you.
For more info.or customized industrial cooling solutions,please contact Lena Qin:
Industrial cooling expert,professional telecom cabinet air conditioner designer & manufacturer.