Drinking Water Filter System For the treatment of factory sewage
Our company-Xinshengtai (XST) Water Treatment Technology Co. Ltd
(Formerly Xi’an Shengtaihuagong Science & Technology Co., Ltd.) was founded in 2003.
It’s an environmental friendly hi-tech company that specializes in research, production, and sale of water treatment equipment for more than 15 years. We now have 150 staff, with 60% of which have
senior or advanced title. And we established long term partnership with many universities and scientific
research institutions in Xi’an. We manufacture machines and do projects as well, since established, we have done many water treatment projects both at home and abroad. With experienced technicians and professional sales team, we will provide you the best solution and service to our customers.
Our main products include: RO system, UF system, EDI system, water softener, water filters, FRP tanks, membranes, membrane housings, etc. Besides standard products, we can also do customized products.
Main component list:
1.Standard back flushing pump(with electric machine)/inlet solenoid valve
2.Back flushing dosing device/5μm precision filter/integrated membrane housing
3.DOW membrane/ Hydraulics
4.Automatic chemical self washing mechanism/baking finish or S.S frame
5.Supervisory meters,such as concentrated water pressure gauge,flow meter,conductivity apparatus
6.Automatic control
Standard system:
Model | Capacibility | Operation | Inlet | Membrane | Membrane (QTY) | Recovery | Power |
(Tons/Hr) | (MPa) | Size(MM) | Size(inch) | (KW) | |||
XSTRO-125L | 0.125 | 1.0-1.4 | DN20 | 40×21 | 1 | 30% | 1.1 |
XSTRO-250L | 0.25 | 1.0-1.4 | DN20 | 40×40 | 1 | 50% | 1.1 |
XSTRO-500L | 0.5 | 1.0-1.4 | DN20 | 40×40 | 2 | 50% | 1.5 |
XSTRO-750L | 0.75 | 1.0-1.4 | DN25 | 40×40 | 3 | 60% | 2.2 |
XSTRO-1000L | 1 | 1.0-1.4 | DN25 | 40×40 | 4 | 60% | 2.2 |
XSTRO-1500L | 1.5 | 1.0-1.4 | DN25 | 40×40 | 6 | 60% | 3 |
XSTRO-2000L | 2 | 1.0-1.4 | DN25 | 40×40 | 8 | 60% | 3 |
XSTRO-250LDP | 0.25 | 1.0-1.4 | DN20 | 40×40 | 3 | 50% | 2.6 |
XSTRO-500LDP | 0.5 | 1.0-1.4 | DN25 | 40×40 | 5 | 50% | 3.7 |
XSTRO-1000LDP | 1 | 1.0-1.4 | DN25 | 40×40 | 10 | 60% | 5.2 |
XSTRO-2000LDP | 2 | 1.0-1.4 | DN25 | 40×40 | 16 | 60% | 7 |
XSTRO-2.5 | 2.5 | 1.0-1.4 | DN32 | 40×40 | 10 | 65% | 4 |
XSTRO-3 | 3 | 1.0-1.4 | DN32 | 40×40 | 12 | 65% | 4 |
XSTRO-6 | 6 | 1.0-1.4 | DN40 | 80×40 | 6 | 65% | 5.5 |
XSTRO-10 | 10 | 1.0-1.4 | DN50 | 80×40 | 10 | 75% | 11 |
XSTRO-15 | 15 | 1.0-1.4 | DN50 | 80×40 | 15 | 75% | 15 |
XSTRO-20 | 20 | 1.0-1.4 | DN65 | 80×40 | 20 | 75% | 18.5 |
1. Q: What is reverse osmosis system?
A: Reverse osmosis is a hot topic in the water treatment industry. Reverse osmosis, is the process of osmosis backwards. Osmosis is the passage of water through a protein membrane (like our skin, or the inside of a plant cell) to equalize the concentration of particles dissolved in the water. The protein membrane allows water to pass through, but molecules larger than water (things like minerals, salts, and bacteria) cannot. Water flows back and forth until the concentration is equal on both sides of the membrane, and an equilibrium is formed.
Let's apply this knowledge to water purification. We want to drink water from a lake or stream, but it contains contaminants like salt, minerals, and bacteria, that make it undrinkable. By applying pressure to water as it passes through a membrane, the water can be forced to move away from the membrane rather than attempting to form an equilibrium like normal. This motion is where the "reverse" comes from. Water is forced through the membrane which blocks an extreme majority of contaminants from coming through.In water treatment, reverse osmosis can usually remove between 96 and 99% of most contaminants, including salts and minerals, dyes, particles, bacteria, and hazardous metals.
2. Q: How does it work?
A: Technical Ruote:
Raw tank-->raw water pump-->quartz sand filter-->activated carbon filter-->water softer-->
Sediment filter (cartridge filter 5um )-->high pressure pump-->RO desalination device-->permeate water tank
3. Q: What types of water sources does it treat?
A: Reverse Osmosis is an ideal water treatment solution in most types of water. Tap water, also known as municipal sources, underground water which includes brackish water, and saltwater. The biggest distinction between these three types is the Total Dissolved Solids (TDS) content of each type. As a rule of thumb, the American Health Association requires that drinking water is under 2,000 PPM TDS. Reverse osmosis is often used in a tap water environment to reduce hardness, or the debris deposited in water from traveling in metal pipes. TDS is often a target of water purification in tap water systems. Underground reservoirs of water are often brackish, meaning they contain large volumes of salt, but not enough to be considered salt water. Groundwater is most often purified for the agriculture industry, the mining industry. Groundwater is also a prized target of the bottling industry, because the unique mineral combinations often have an appealing taste.
Salt water reverse osmosis (sometimes referred to as desalination) is the turning of saltwater into drinking water. Ocean water has up to 45,000 PPM TDS. The biggest uses of desalination come in providing water in areas that lack a regular supply of fresh water.
4. Q: Is the pretreatment necessary?
A: It is very important that feed water be preconditioned to protect the membranes from fouling causing premature failure.The membrane is constructed of a porous material that allows water to pass through, but rejects up to 99% of the dissolved solids at the surface. The dissolved salts are concentrated reject water (brine stream), where they are discharged to waste. Removing things prior is key to letting the RO system do what it was meant to do. As the RO System continues to operate, the dissolved and suspended solids in the feed water tend to accumulate along the membrane surface. If these solids are allowed to build up, they eventually restrict the passage of water through the membranes, resulting in a loss of throughput. (The throughput capacity of the membranes is commonly referred to as the flux rate, and is measured in gallons per square foot of membranes surface area per day.)
5. Q: What determines the precise pretreatment for a particular RO?
A: In one word, analysis, because every source of water is different, and you never know what's in your water until you have it analyzed. The water analysis, LSI, SDI, or CFI values are used to determine the precise pretreatment requirements for a particular RO System. Since water supplies vary considerably from one location to another, each pretreatment requirement will be different.
6. Q:Does the feed water need to be softened by the RO?
A: Ion exchange is a popular method for softening and reducing the potential for mineral scale formation on the membrane surface. Ion exchange softening uses sodium to replace scaleforming ions such as calcium, magnesium, barium, strontium, iron, and aluminum to prevent damage to the membrane elements. The sodium forms very soluble salts, which are readily rejected by the Reverse Osmosis System and do not readily form mineral scales on the membrane surface. A sodiumcycle softener is regenerated with sodium chloride brine. The spent regenerant, along with the softener rinse water, must be discharged to waste. It is because of this that ion exchange is recommended for applications that have high metal contents in the treated water.
7. Q: what’s the basic information should provide for quotation?
A: 1) raw water and TDS of raw water; 2) the outlet water requirements, and also the usage; 3) capacity customer need.
8. Other details information, please kindly contact us any time.