Detachable Multi Jet Mechanical heat meter M-BUS, RS-485, Pulse output for choice
OverviewQuick DetailsPlace of Origin:Zhejiang, China (Mainland)Brand Name:OEMModel Number:YG-RLM(F)-15-25Feature:removablenonmagneticAccuacy
$1 /
Stock: 10000 s
Quantity:
-+
Min Order: piece
Buy Now
Add To Cart
Send Inquiry
Seller Support:
Trade Assurance — To protect your orders from payment to delivery
Product Details
Transaction Comments
Overview
Quick Details
Place of Origin:
Zhejiang, China (Mainland)
Brand Name:
OEM
Model Number:
YG-RLM(F)-15-25
Feature:
removable&nonmagnetic
Accuacy:
Class 2
Label:
English or Russia
Installation:
Inlet or outlet
Measurement:
KW/H, Gcal
Communication:
M-BUS or RS-485, Infrared port, pulsed output
Size:
DN15mm, DN20mm, DN25mm
Flow rate:
Qn = 0.6m3/h, Qmax = 1.2m3/h, Qmin = 0.024m3/h
Voltage for RS-485:
15V to 24V for Russia
Voltage for M-BUS:
3.6V
Supply Ability
Supply Ability:
30000 Piece/Pieces per Month
Packaging & Delivery
Packaging Details
Packing in export carton
Port
Ningbo

                                 Detachable Multi Jet Mechanical heat meter M-BUS, RS-485, Pulse output for choice

                                                               

                                                 RLM(F)-15

 

Description:

 

Models and Specifications

Model

Qn(m3/h)

Length(mm)

DN(mm)

Sensor length 

   Display

Romote

   Class

RLM(F)-15-0.6

     0.6

      110

15

      1.5m

   kw/h

M-BUS

       2

RLM(F)-15-0.6

     0.6

      110

15

      1.5m

   Gcal

RS-485

       2

RLM(F)-15-1.5

     1.5

      110

15

      1.5m

   kw/h

M-BUS

       2

RLM(F)-15-1.5

     1.5

      110

15

      1.5m

   Gcal

RS-485

       2

RLM(F)-20-2.5

     2.5

      130

20

      1.5m

   kw/h

M-BUS

       2

RLM(F)-20-2.5

     2.5

      130

20

      1.5m

   Gcal

RS-485

       2

RLM(F)-25-2.5

     2.5

      160

25

      1.5m

   kw/h

M-BUS

       2

RLM(F)-25-2.5

     2.5

      160

25

      1.5m

   Gcal

RS-485

       2


Features:


1. Flow-rate range: 0.6~2.5m3/h.
2. Min. temperature difference 3℃
3. Horizontal/vertical installation
4. Embedded and removable installation design to prevent damage during the adjustment period
5. Smart multi-flow design, capable of recording flow rate and volume
6. Advanced nonmagnetic sensing technology
7. High precision design, meeting Class 2 metering requirements of EN1434 and CJ128 standards
8. A lithium battery with service life exceeding six years
9. Optional remote RS485 or M-BUS output, convenient for remote systems
10. Payment settlement date renewable, 18-month data storage
11. 360 degree revolving monitor for easy reading
12. Inclined LCD for optimized viewing
13. Wide measuring range (q s/q i =100:1)
14. Low startup flow rate
15. Capable of measuring both heat and cold energies
16. For use at water inlet end (heat meters for return water end are available at the request of users)
17. PT1000 temperature sensor pair
18. Environment class: A

Main Technical Parameters:

 

Normal Flow(Qn)

0.6m3/h

1.5m3/h

2.5m3/h

Flow range(m3/h)

0.012~1.2

0.03~3

0.05~5

  Pressure loss(KPa/Qp)

Reference diagram I

24

24

24

Start flow(L/h)

3

5

7

Max. Pressure(MPa)

1.6

Temperature range()

4~95

 


Pressure Loss Diagram:

 


Detachable Multi Jet Mechanical heat meter M-BUS, RS-485, Pulse output for choice


Measuring Features:


1.Water pressure: No more than 1Mpa
2.Measuring Class & Max. Tolerance
This product is for Class 2 measurement, and the max tolerance is shown in the curve below: 


E=±(3+4Δθmin/Δθ+0.02qp/q)%
Therein, Δθmin means the minimum temperature difference, and Δθ the actual temperature difference.

Dimensional Parameters:

 

Normal flow(Qn)

m3/h

0.6

1.5

2.5

Normal DN

mm

15

15

20

Body thread

----

G3/4B

G1B

G3/4B

G1B

G1B

G1 1/4B

Connection thread

----

1/2

3/4

1/2

3/4

3/4

1

Height

mm

112

115.5

112

115.5

115.5

119.5

Length

mm

110

110

110

110

130

130

 


Pipeline Installation Diagram (for Meters Used at Inlet or Outlet for option):


Detachable Multi Jet Mechanical heat meter M-BUS, RS-485, Pulse output for choice

 

 

EXPLOSION:

 

 

 

Detachable Multi Jet Mechanical heat meter M-BUS, RS-485, Pulse output for choice 

 

 

COMPANY PHOTOS

 

 

Detachable Multi Jet Mechanical heat meter M-BUS, RS-485, Pulse output for choice

 

Detachable Multi Jet Mechanical heat meter M-BUS, RS-485, Pulse output for choice 

 

More Heat Meters, please have a view of our website:  

 

         

Our Contact:

 Detachable Multi Jet Mechanical heat meter M-BUS, RS-485, Pulse output for choice

 

 

 

 

 

Other products from this supplier
Back to top
X
Added successfully
You have added this product to the wish list successfully !
X
Added successfully
It has now been moved to the top of the list!
Continue shopping
X
Add a New List
Save
cancel