DOG-3082 Industrial DO meter dissolved oxygen meter price
DOG-3082 Industrial Dissolved Oxygen Meter is a kind of high-intelligence in-line meter that is developed by our company and used for continuous on-line monitoring. It can be equipped with DOG-208F Polarographic Electrode and can automatically switch from ppb level to ppm level of wide-range measurement. This instrument is designed for monitoring the oxygen content in the boiler feed water, condensate water and sewage.
Features
All the data are displayed in English. It can be easily operated: |
It has a complete elegant interface: Liquid crystal display module with high resolution i |
There is no symbol or code that is defined by the manufacturer. |
Simple menu structure and text-type man-instrument interaction |
It adopts classified menu structure which is similar to that of a computer, clearer and more convenient. |
It is not necessary to remember the operation procedures and sequences. |
It cane operated according to the prompts on the screen without the guidance of an operation manual. |
Multi-parameter display: The oxygen concentration value, input current (or output current), |
temperature values, time and status can be displayed on the screen at the same time. |
The main display can show the oxygen concentration value in a 10 x 10mm size. |
As the main display is eye-catching, the displayed values can be seen |
from a long distance away. Six sub-displays can display such information as the input or |
output current, temperature, status, week, year, day, hour, minute and second, so as to |
users’ habits and to conform with different reference times set by the users. |
Technical Indexes
1. Measuring range: 0~100.0ug/L; 0~20.00 mg/L (automatic switching); (0-60°C);(0-150°C)Option |
Resolution: 0.1ug/L; 0.01 mg/L; 0.1°C |
2. Intrinsic error of the whole instrument: ug/L: ±l.0%FS; mg/L: ±0.5%FS, temperature: ±0.5°C |
3. Repeatability of the indication of the whole instrument: ±0.5%FS |
4. Stability of the indication of the whole instrument: ±1.0%FS |
5. Automatic temperature compensation range: 0~60°C, with 25°C as the reference temperature. |
6. Response time: <60s (98% and 25°C of the final value) 37°C: 98% of the final value < 20 s |
7. Clock accuracy: ±1 minute/month |
8. Output current error: ≤±l.0%FS |
9. Isolated output: 0-10mA (load resistance <15KΩ); 4-20mA (load resistance <750Ω) |
10. Communication interface: RS485 (optional) (Double power for option) |
11. Data storage capacity: l month (1 point/5 minutes) |
12. Saving time of data under a continuous power-failure condition: 10 years |
13. Alarm relay: AC 220V, 3A |
14. Power supply: 220V±10% 50±1HZ, 24VDC(option) |
15.Protection: IP54, Aluminium she |
16. Size: secondary meter: 146 x 146 x 150 mm; dimension of the hole: 138 x 138mm |
17. Weight: 1.5kg |
18. Working conditions: ambient temperature: 0-60°C; relative humidity <85% |
18. The connection tubes for inlet and outlet water: Pipes and hoses |
|
|