Uphold the usual rigorous design CONAI escalator/travelator to the quality of the “security” of the enterprise foothold. Fully taken into acount in detail the passengers need to bring people to a moreharmonious, more secure passenger line environment.
01 Skirt panel Brush
The brush that has been installed between the skirt panel.
02 Comb entrance
Escalator up and down site, the entrance to the steps and comb yellow police tape.
03 Emergency stop button
When the button is pressed, the escalator(travelator) will stop running.
04 Lower rotating station security
When the step chain run, double protection
05 Main drive monitoring functions
Automatically stop running when speeding and deceleration(escalator or travelator)
06 Drive-chain breaking protection
When the drive chain is stretched, it will be automatically tightening. And while at break, the chain will automatically stop running.
07 Step(tread) sunk protection device
When there is abnormal step bending,the escalator(travelator) will be stopped for running before the step entering into the comb plate
08 Handrail Speed measuring device
Handrail speed ratio steps slower than a cetain percentage of the escalator(travelator) will stop running.
1 Lack of phase,error phase protection | If lack of phase or error phase has been checked out, the escalator (moving-walkway) will automatically stop the operation
|
2 Motor over-load protection | When the current exceeds 15% of the current rating. The escalator will automatically stop the operation.
|
3 Electrical appliance loop protection | It offers the automatic circuit diaconnecting device to protect the circuit and mains components of the escalator(moving-walkway)
|
4 Handrail inlet protection | When some outside substance has been clipped in the handrail inlet, the escalator(moving-walkway) will automatically stop running
|
5 Comb plate safety device | When some outside substance has been clipped in or between the combs, the escalator(moving-walkway) will automatically stop running |
6 Step sagging protection device | When there is abnormal step bending, the escalator(moving-walkway) will automatically stop running
|
7 Broken drive-chain safety device | When the drice-chain has been orver-streched or it is broken, the escalator(moving-walkway) will automatically stop running
|
8 Broken step chain protection | When step(plate) chain has been over-stretched or it is broken, the escalator(moving-walkway) will automatically stop running
|
9 Over-speed protection | When there is over-speed to the escalator(moving-walkway), it will automatically stop running
|
10 Direction reversal protection | When it comes the uninternational reversal of the direction of travel, the escalator(moving-walkway) will automatically stop running
|
11 Security line | The yellow synthetic resin security line is located in the front position and two sides of the escalator tread so that the passenger will not tread in-between the edge of the adjacent step and the lift group lengthened skirt panel. The security line on both sides of the step is higher than the tread surface.(The moving-walk offers the selective yellow spray-painted security line.)
|
12 Emergency stop button | When the button has been pressed down, the escalator(moving-walkway) will automatically stop running
|
13 Skirt panel protection | When the button has been pressed down, the escalator(moving-walkway) will automatically stop running
|
14 Brake protection | When the electric force falls short of supply or it acts any of the safety device, the brake function goes into effect by the safety device through the spring resilience action. In this way, the escalator(moving-walkway) stop running
|
15 Safety inspection switch | It is a safety device to prevent from the escalator starting during the inspection and maintenance.
|
17 Step illumination | Illumination exists in the upper and lower ends of the escalator, in the lower part of the step in order to remind the passengers of the security matters
|
17 Alarm bell starting device | The alarm bell rings when it starts the escalator in order to remind the passenger of the security matters
|
18 Control device for handrail breakage | When the handrail is broken, the escalator will automatically stop running
|
19 Skirt panel brush | The brush that has been installed between the skirt panel and the step will prevent the passengers from touching the skirt panel.(It is not merely restricted to the escalator)
|
Single unit
The single unit used to link two levels. It is suitable for buildings with passenger traffic flowing mainly in one direction. Flexible adjustment to traffic flow(e.g. up in the morning and down in the evening ) is possible.
Continuous arrangement(one-way traffic)
This arrangement is used mainly in smaller deparment stores to link three sales leves. It requires more space than the interrupted arrangement.
Interrupted arrangement (one-way traffic)
This arrangement is somewhat inconvenient for users. But advantageous for department store owners, since the short detour to the next unit adn the spatial separa-tion between up and down travel is ideal for leading customers past strategically placed advertising displays.
Parallel, interrupted arrangement (two-way traffic)
This arrangement is used in mainly in departement stores and public transport buliding with a heavy traffic volume. When there are three or more escalators it should be possible to reverse the traveling direction according to the traffic flow. This arrangement is economical. Since no inner lateral claddings are rquired.
Crisscross, continuous arrangement(two-way traffic)
This arrangement is used mainly in major department stores, public buildings and public transport buildings where transport times between several levels should levels should be kept to a mininum.