40*40mm Single Diode Voltmeter Analog Panel Meter |
Supply-Battery Panel Meter
Application:
91L16,91L18,91L19,91L4,85L17,85L1 and 85C1 series voltmeter are applicable to voltage stabilizer,Battery charger,Automatic Charger,Generator,Electric Power Inverter Equipment and so on.
91L16 series Square Panel Meter
Full Outer Size:40*40mm
Spec:0-300V,0-120V;0-15A/20A/30A/50A
Material Remark:
1. This 40*40mm item panel meter,my factory often make White Magnet material(Beterry Quality)and Black Magnet material(Normal Quality).And this items panel meter often include product line like as:sinlge diode meter and Double Diode Meter.
2. about the Scale Plates Material,my factory can supply to the Aluminous and Plastic Material to choose.
Packing Detail:
Normal Quality:50pcs/box,2000pcs/CTN
Better Quality:100pcs/foam box;1200pcs/CTN
Best Quality:50pcs/foam;1000pcs/CTN
91L18 Series Square Panel Meter
Full Outer Size:55*48mm
Spec:0-300V,0-120V;0-15A/20A/30A/50A
Material Remark:
1. This 55*48mm item panel meter,my factory often make White Magnet material(Beterry Quality)and Black Magnet material(Normal Quality).
2. about the Scale Plates Material,my factory can supply to the Aluminous and Plastic Material to choose.
Packing Detail:100pcs/foam box;900pcs or 1000pcs/CTN
91L19 Series Square Panel Meter
Full Outer Size:45*48mm or 48*45mm
Spec:0-300V,0-120V;0-15A/20A/30A/50A
Material Remark:
1. This 48*45mm item panel meter,my factory often make White Magnet material(Beterry Quality)and Black Magnet material(Normal Quality).
2. about the Scale Plates Material,my factory can supply to the Aluminous and Plastic Material to choose.
Packing Detail:
Normal Quality:40pcs/box;1600pcs or 2000pcs/CTN
Better Quality:100pcs/foam box;900pcs or 1000pcs/CTN
91L4 Series Square Panel Meter
Full Outer Size:45*45mm
Spec:0-300V,0-150V;0-15A/20A/30A/50A
Material Remark:
1. This 45*45mm item panel meter,the main application to the Generator equipment.My factory often make the High quality White Magnet material.
2. about the Scale Plates Material,my factory can supply to the Aluminous to choose.
Packing Detail:
Normal Quality:1pcs/box;200pcs/CTN
85L17 Series Square Panel Meter
Dimensions:56*64mm
Measuring Range:0-150V/300V/500V/500V;0-15A/20A/30A/50A
Material Remark:
1. This 85L17 series panel meter,It has been widely used in a variety of AC and DC transmission and distribution systems, power control panels and other electrical devices.My factory often make the High quality White Magnet material.
2. about the Scale Plates Material,my factory can supply to the Aluminous to choose.
Packing Detail:2pcs/box;500pcs/CTN
85L1 and 85C1 Series Square Panel Meter
Dimensions:56*64mm
Measuring Range:0-150V/300V/500V/500V;0-15A/20A/30A/50A
Material Remark:
1. This 85L1 and 85C1 series panel meter,It has been widely used in a variety of AC and DC transmission and distribution systems, power control panels and other electrical devices.My factory often make the High quality White Magnet material.
2. about the Scale Plates Material,my factory can supply to the Aluminous to choose.
Packing Detail:1pcs/box;500pcs/CTN
Export Country:This panel meter main export to Middle East Market,South America,and Africa Market.Such as Dubai,India,Pakistan,Bangladesh,Vietnam,Myanmar;South Africa,Brazil,Russia and so on.
Application:
Voltage Stabilizer, Battery Charger, Automatic Charger, Generator, Electric Power Inverter Equipment.
Uses and applications:
This series of meters is a direct imitation of power measurement display instruments, measuring DC current and voltage, AC current and voltage, frequency, power factor, phase sequence, power, synchronization instructions and other non-power measurements. It has been widely used in a variety of AC and DC transmission and distribution systems, power control panels and other electrical devices, in the industries of maritime shipping, rail transport, chemical flameproof, low voltage equipment, construction equipment, generators, machinery equipment, etc. Being able to make electrical measurement and non-power measurement, it is a high-end instrument applied in general environmental conditions.
Standards and certifications:
The Jingying series of pointer meter is produced on the standard of GB/T7676-1998, and the digital meter is on the standard of GB/T22264-2008. Its safety performance is on the standard of GB4793 and IEC61010. The dial scale line and the pointer is designed to meet the German standards of DIN43790 and DIN43802. The shape and hole size of the meter is on the standards of GB/T1242 and IEC61554. All the products of Jingying meters Company have gone through the national CE certification, and have got ISO: 9001 certification.
The outer casing of the panel meter:
The base of the series of JY meters is made of TBT flame-retardant plastic, and its vicat temperature is 130°C. The outer shell is made of ABS flame-retardant plastic, and its vicat temperature is 85°C.
Changes caused by the temperature:
Temperature range for reference: 23°C±2°C, 13°C~23°C, and 23°C~33°C. The changes caused by the impact of temperature are not allowed to be out of the range of the level index ±100%.
The installation:
Unless specified, the meter is usually installed in a vertical position. Other installation positions such as horizontal and inclined position can be installed according to the customer’s requirements. The corresponding level of accuracy is only valid to the regulated installation position. The meter has two kinds of instruction angles: right angle 90°and wide angle 250°.
Anti-vibration and anti-shock:
Anti-vibration: complies with the standard of IEC60068-2-6; frequency sweep range: 10-55-10Hz; displacement amplitude: ±0.15mm, ±0.3mm; frequency sweep cycles: 5 times; sweep rate: 10ct/min; maximum acceleration: 147m/s2(15g), 490m/s2(50g); RMS acceleration: 6.06g;vibration time: 15 min. Anti mechanical shock: complies with the standard of IEC60068-2-27.
Accuracy level:
The JY series of pointer meter: AC and DC voltmeter and ammeter to the level of 1.5 or 2.5, power meter to the level of 2.5, frequency meter to the level of 2.5, and power factor meter to the level of 2.5.
Overload ammeter:
The conventional overload multiple times should be once or twice, and it can be customized to once, twice, 3 times and so on according to the user’s requirements. Its function is to indicate the approximate transient overload current value, such as the start-up current when the motor stars, and so on.
Extrinsic current shunt:
The voltage specifications of the extrinsic current shunt of DC ammeters are 150mV,100mV,75mV,60mV and 50mV, which can be customized. The resistance of the conducting wire connecting the meter and the current shunt should within the range of 15∼25mΩ, to ensure the accuracy of the meter.
The surface of the dial:
The surface of the dial uses aluminum alloy, white paint, black ink printing or laser printing. The dial can be customized according to the customer’s sample dials (overprint colors can be customized). The luminous dial uses the PC panel.
Zero regulator:
Except the reading meters without mechanical zero, all other meters have pre-positive zero regulator, used to adjust the meter’s mechanical zero.