Industrial Brush
Civilian Brush
Brush Equipment
Brush Raw Materials
Decoration Materials
∨
∧
Quantity(Pieces) | 1 - 1000 | 1001 - 5000 | >5000 |
Est. Time(days) | 3 | 7 | To be negotiated |
Model | HS-200-5 | HS-200-12
| HS-200-24
| |||
Output | DC Output voltage | 5V | 12V | 24V | ||
Voltage tolerance | ±1% | ±1%
| ±1%
| |||
Output current | 40A | 16.5A | 8.3A | |||
Current range | 0~40A | 0~16.5A | 0~8.3A | |||
Output Power | 200W | 199W
| 199W
| |||
mVp-p | 120mVp-p | 150mVp-p | 180mVp-p | |||
Adjust range for DC Voltage | ±10% | ±10% | ±10% | |||
Start/Rise hold time | 800ms,20ms,24ms/230VAC.1200ms,30ms,20ms/115VAC | |||||
Input | Input voltage range | 85~132VAC 170~264VAC 47~63Hz,240~370VDC | ||||
Input AC | 4.5A/115V 2.5A/230VAC | |||||
Efficiency | 80% | 83%
| 85% | |||
Impulse current | CCA 25A/115V 50A/230V | |||||
SILC | <1mA/240VAC | |||||
Protection | Overload protection | Start-up Overload Protection of 105%~150% Rated Output Power | ||||
Protection mode: hiccup mode, automatic recovery after removal of abnormal load conditions | ||||||
Over voltage protection | Start-up Overvoltage Protection of 105%~135% Rated Output Voltage | |||||
Protection mode: hiccup mode, abnormal condition can be removed and normal output can be automatic restored. | ||||||
OTP | ≥85℃±5℃(Detection of TSW1 on the radiator of power transistor) | |||||
Protection mode: Turn off the output and automatically recover after the temperature returns to normal. | ||||||
Work environment | Working temperature and humidity | -10℃~+60℃;20%~90%RH |