Specification of memory SD card
1. Type: SD card(If control much led lights, high speed SD card will be recommended)
2. Memory: 1GB
3. Format: Support FAT and FAT32
4. Save Fat:*.led
Using and note
1. K-16000S led controller support online work and offline work. It support ARTNET and MADRIX software.
2. How to choose and adjust chip types? You When you choose chip type, the led controller must be offline work. If online work, you can not choose chip type.
3. When it is online work, you need use LEDMAGIC software to make programs. You do not need to choose the concrete chip type.When it is offline work, you need use LEDEDIT2014 to make programs and choose controller model K-8000ALL. Do not need to choose chip type.
4. When many controllersynchronization, each controller can support different chip type. As for K-16000S, it has 16 ports, so you need to make 2pcs K-8000 programs and modify the two program file name into 00-0.led and 01-0.led. Then copy the programs to SD card. Modify the program name into 00.led and 01.led, then copy the programs into SD card.
5. When offline work, press SET button to choose chip type. Support chip types: UCS19XX, UCS29XX, TM18XX, WSD281X, SM1670X,GS8205, GS8206, 6812, 9823, 9883, TM1914, LPD1886, DMX512, UCS512, WS2822 etc. If want to add other support chips, please contact us.
6. Button set the wanted playing speed and chip, you need to wait about 8 seconds to save the setting. Next time to open it, you do not need to reset it.
7. Many controllersynchronization can be achieved though net cable connection. Net cable should be connected NET OUT of the first controller to NET IN of the second controller.
Setting about connecting computer though ARTNET protocol.
1. This controller support ARTNET protocol. It can be widely be applied to lights effect software and other control device which support artnet protocol, such as Madrix software.
2. When connect to computer, need to set the led controller. Just need to set the first controller which connected the computer. The other controller do not need to be set.
3. As for ARTNET and MADRIX, three points need to be set as bellow. The first one is to set pixels of each port. Press buttons tochoose. There are 4 options. They are 170pixels, 340pixels, 510pixels and 680pixels. The second is to internet IP address. Just need to set the last one of IP. Default setting is 190-200 etc. The third is to set occupy lines quantity of the whole ARTNET IP. Max 256 lines, each line correspond 512 pixel DMX512. 512/3=170.6. Max pixels are 43,520(170*256), when setting 680pixel per line. That is to say, it occupy 4 lines of artnet. One K-16000S controller occupy 64lines of artnet(4*16ports).In this way, Max 4pcs K-16000S controller synchronization and max pixels are 43,520. If you want to control more than 43,520 pixels, you need to add network card to computer.
4. Computer is power off. Press SET button enter into setting mode. LED display will show setting the first point of 4 HXXX options, They are H170, H340, H510, H680. The four option decide how may pixels per lines of K-16000S controller. Press SPEED+ and SPEED- buttons to choose. Then press MODE to set the second point. LED display will show FXXX which is used to set this led controller and other synchronic controller occupy the lines of ARTNET IP. They are F016, F032, F064, F128, F256 options.F016 means all controllers only occupy 16 ARTNET lines. Each line is 512 pixel, 16*170pixels. F256 means full occupy the whole artnet. User can set based on pixels of lights. Then press MODE button, LED display will show CXXX, XXX represents three numbers, the three numbers are the last IP of this master controller. Generally it is set to 190-200. In order to avoid conflict, the first three IP addresses are not need to set. Controller will adjust it is consistent to the first three address. For example, set it to be C195, connecting to computer IP is 192.168.1.100. then this master controller ip address is set to be 192.168.1.195. After the three point setting, then press SET button, it enter into normal online mode. LED display will show L001 which mean this master controller is the first controller connected to computer. At last ,finish the setting.