ITEM |
TEST STANDARD |
|||
NPO(N) |
X7R(B) |
Y5U,Y5V(Y) |
||
Capacitance |
WITHIN THE TOLERANCE |
WITHIN THE TOLERANCE |
WITHIN THE TOLERANCE |
|
Dissipation Factor |
≤0.15% |
≤3.5% |
≤7%(less than 220nF) ≤10%(220~470nF) ≤15%(470~1000nF) |
|
Insulation Resistance |
C≤10NF IR>10000MΩ C>10NF R .C>100S |
C≤25NF IR>4000MΩ C>25 NF R.C>100S |
||
Voltage Test |
Test voltage:2.5.rated voltage The charging current may not exceed 50 mA. Duration of test:5 seconds |
|||
TEST CONDITION | ||||
FREQUENCY |
1M HZ (C>1000PF,1KHZ) |
1KHZ |
||
TEST VOLTAGE |
1VDC |
0.5 VDC |
||
TEST VOLTAGE OF IR |
The measuring voltage is equal to the rated voltage. The charging current may not exceed 50 mA |
|||
Standard atmospheres conditions |
Unless otherwise specified, the standard range of atmospheric conditions for measuring and testing is as follows: Ambient temperature 15°C~35 °C Relative humidity 45%~75% Air pressure 86Kpa~106Kpa (860-1060mbar) If there may be any doubt on the results, measurements shall be made within the following limits: Ambient temperature 25°C±1 °C Relative humidity 48%~52% Air pressure 86Kpa~106Kpa (860-1060mbar) |
|||
Operating temperature range |
The operating temperature range is the range of ambient temperatures at which the capacitor can be operated continuously at rated voltage. Temperature compensation use: NPO -55°C~+125°C X7R -55°C~+125°C |